摘要
针对塔式太阳能热发电站的工艺特点,对其发电区较常规火电机组总平面布置的不同之处进行阐述。依托国内外工程经验,系统总结发电区的位置、组成、布置原则,对发电区布置格局中的汽机房、空冷平台、电气构筑物区、储热及蒸汽发生器区、水处理及供水设施区以及污废水设施区进行详细描述,并给出塔式太阳能热发电站发电区总平面布置实例。
In view of the technological characteristics of tower solar thermal power station,this paper expounds the layout differences between its power block and conventional thermal power plant.Based on domestic and foreign engineering experiences,the location,composition and layout principle of the power block in tower solar thermal power station have been systematically summarized.The general arrangement of the turbine house,ACC platform,electrical structure area,heat storage and steam generator area,water treatment and supply facilities area and sewage facility area in power block are respectively described in detail.Besides,a project case is given.
作者
孙鹏
彭兢
SUN Peng;PENG Jing(Northwest Electric Power Design Institute Co.,Ltd.of CPECC,Xi'an 710075,China)
出处
《电力勘测设计》
2019年第3期65-69,共5页
Electric Power Survey & Design
关键词
太阳能
塔式发电系统
发电区
总平面布置
ar power
solar power tower system
power block
general layout