摘要
采用波纹钝体燃烧器代替船体燃烧器并将各次风下移等手段对广州发电厂 2 2 0t/h锅炉燃烧器进行改造 ,成功地消除了锅炉燃烧器喷口经常烧坏的故障 ,使锅炉各参数达到了设计要求。图 3表 3参
The burner of a 220t/h boiler of the Guangzhou Power Plant has been refitted by substituting the marine type burner for a corrugated blunt type burner, where by the problem of frequent occurrence of burning damage of the burner's nozzle has been solved with all boiler paramenters meeting design valves. Figs 3, tables 3 and refs 2
出处
《发电设备》
2002年第6期4-6,共3页
Power Equipment