上海惠南水厂生物预处理生产试验结果

Results of Biological Pretreatment Operation Test at Shanghai Huinan Water Plant
下载PDF
导出
摘要 惠南水厂位于上海,水源水受工业污水和生活污水的污染,不符合生活饮用水水源水质的要求。采用接触氧化法进行预处理,可使整个制水工艺NH3-N,CODMn的去除率分别提高78.7和15.45个百分点。 Huinan Water Plant is located in Shanghai. The water at its water source was polluted by industrial wastewater and domestic sewage and did not meet the requirements for water quality at the water source of domestic water and drinking water. The use of contact oxidation process in the pretreatment improved the NH3-N and CODMn removing efficiencies of the entire water preparation process by 78.7% and 15.45% respectively.
出处 《工业用水与废水》 CAS 2002年第5期10-12,共3页 Industrial Water & Wastewater
关键词 上海惠南水厂 生物预处理 生产试验 接触氧化 Huinan Water Plant biological pretreatment contact oxidation