摘要
选取夏热冬暖地区典型煤矸石烧结砖模型,配以不同的材料对相应的墙体进行传热系数的计算,得出各种匹配方案下的传热系数,研究了材料导热系数、孔洞排数及孔洞排列方式对砖块传热系数的影响及一般规律,指出了煤矸石烧结砖优化设计时应注意的问题并提出了相应的建议。
After typical gangue baked brick models are chosen, heat transfer coefficient of the wall is calculated fitted with different kinds of scheme. Then kinds of influences on the heat transfer coefficient by material thermal conductivity coefficient, holes row number and arrangement mode are analyzed. And finally followed with some points for attentions and suggestions when designing coal gangue fired brick.
出处
《砖瓦》
2016年第10期28-32,共5页
Brick-tile
关键词
煤矸石烧结砖
建筑节能
夏热冬暖地区
优化设计
coal gangue fired brick
building energy efficiency
hot summer and warm winter zone
optimal design