摘要 设计一款智能心率监测系统,主要应用于老年人和中年人的智能穿戴领域,其便携式的心率测量使用方便。采用反射式光电传感器作为前端信号采集,将得到的信号进行转换和数字滤波,经过心率计算后得到的数据无线传输给监控终端,可实现智能化和网络化的实时监测。当接收到的心率测量数据不在人体心率安全范围内时,系统会启动报警,可及时避免突发疾病因时间耽误急救。该系统设计经过多种运动状态试验对比,表明此设计的智能心率监测系统具有稳定性、高精度和可行性。 An intelligent heart rate monitoring system is designed,which is mainly used in the intelligent wearable fields ofthe elderly and middle?aged people,and is convenient for portable measurement of heart rate.The reflective photoelectric sensoris used to acquire the front?end signal,then the transformation and digital filtering are performed for the received signal,andthe data calculated with heart rate monitoring system is transmitted to the monitoring terminal in the wireless form to realize theintelligent and networked real?time monitoring.If the measured heart rate data received by the signal acquisition module is out ofthe security scope of human heart rate,the system will start the alarm to timely prevent the delay before the first aid of paroxys?mal disease comes true.The experimental contrast was conducted for the system design with a variety of motion conditions.Theexperimental result shows that the intelligent heart rate monitoring system has high stability,high accuracy and strong feasibility.
作者 刘宇红 李月婷 何国锋 姜成旭 LIU Yuhong;LI Yueting;He Guofeng;JIANG Chengxu(College of Big Data and Information Engineering,Guizhou University,Guiyang 550025,China)
出处 《现代电子技术》 北大核心 2017年第20期117-120,123,共5页 Modern Electronics Technique
基金 贵州省科技计划项目科技基础条件平台:基于物联网的智能监护大数据云服务平台(黔科合平台人才[2016]5707)
关键词 反射式光电传感器 智能穿戴设备 高精度数字滤波 信号采集 reflective photoelectric sensor smart wearable device high.precision digital filtering signal acquisition
  • 相关文献

参考文献6

二级参考文献53

  • 1陈明进,许锡铭.脉搏血氧饱和度仪的发展及应用[J].现代医学仪器与应用,1995,7(1):5-10. 被引量:6
  • 2王小美.脉搏血氧饱和度监测在ICU中的应用[J].医疗卫生装备,2006,27(2):68-68. 被引量:6
  • 3张红蕾,李斌.SPO_2监护的原理与局限性及对策的讨论[J].医疗设备信息,2006,21(2):21-21. 被引量:5
  • 4XIN Shang-zhi,HU Sijung,CRABTREE Vincent P.,ZHENG Jia,AZORIN-PERIS Vincent,ECHIADIS Angelos,SMITH Peter R..Investigation of blood pulse PPG signal regulation on toe effect of body posture and lower limb height[J].Journal of Zhejiang University-Science A(Applied Physics & Engineering),2007,8(6):916-920. 被引量:2
  • 5Wang X, Ooi B T. Unity PF current-source rectifier based on dynamic trilogic PWM[J]. IEEE Transaction on PE, 1993,8(3) : 288 - 294.
  • 6McGrath B R Holmes D G A comparison of multicarrier PWM strategies for cascaded and neutral point clamped multilevel inverters[ C ]. Power Electronics Specialists Conference, 2000. PESC 00. 2000 IEEE 31st Annual, 2000, 2 : 674 - 679.
  • 7Teodorescu R, Blaabjerg F, Pedersen J K et al. Multilevel converters-a survey[ C ]. EPE'99 CDROM, 1999.
  • 8Zhang Zhongchao, Boon-Teck Ooi. Forced commutated HVDC and SVC based on phase-shifted multi-converters[ J ]. IEEE Trans. on Power Delivery, 1993,8(2) : 712 - 718.
  • 9Holmes D G Opportunities for harmonic cancellation with carder-based pwm for two-level and multilevel cascaded inverters[ J ].IEEE Trans. on Industry Applications, 2001,37(2) : 574 - 582.
  • 10Mendelson Y,Lewinsky RM,Wasserman Y.Multi-wavelength reflectance pulse oximetry.Anesth Analg:2002 Jan; 94(1 Suppl):S26-30.

共引文献95

同被引文献29

引证文献4

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部