淮阴三站空箱裂缝成因及处理措施分析 被引量:1

Analysis on causes and treatment measures of empty case cracks in Huaiyin Third Stage Pumping Station
下载PDF
导出
摘要 结合淮阴三站变频器层空箱在工程投入运行以后发现的贯穿裂缝现象,对空箱贯穿裂缝的成因进行了具体分析和研究,提出了裂缝成因分析的结论和后期进行裂缝处理的措施。此研究内容可为南水北调东线工程其他泵站存在的贯穿裂缝处理提供借鉴。 The phenomenon of penetration cracks discovered after the operation of empty case project in Huaiyin Third Stage Pumping Station frequency converter is combined for concrete analysis and study on causes of empty case penetration cracks.Conclusion of crack causes and subsequent crack treatment measures are proposed.The research contents also have certain reference role to penetration crack treatment in other pumping stations in eastern route of South-to-North Water Diversion Project.
作者 杨二洋 何庆 杨俊 YANG Eryang;HE Qing;YANG Jun(Jiangsu Irrigation General Canal Management Office,Huai’an 223001,China)
出处 《水利建设与管理》 2018年第3期73-75,共3页 Water Conservancy Construction and Management
关键词 空箱裂缝 成因 处理措施 empty case cracks cause treatment measures