实时超声弹性成像对足底筋膜炎的诊断价值 被引量:15

Diagnosis of Real-time Elastosonography in Plantar Fasciitis
下载PDF
导出
摘要 目的探讨实时超声弹性成像对于B超未发现足底筋膜炎筋膜形态学改变的诊断价值。资料与方法纳入36例足底筋膜炎患者(42只足)作为研究组,并选择24例健康志愿者(48只足)作为对照组。采用B超图像测量筋膜最大厚度;采用实时超声弹性成像图像对筋膜进行弹性图像评分;并计算相对周围软组织的应变率。比较各种方法的诊断价值。结果研究组筋膜厚度、弹性图像评分、应变率均高于对照组,差异有统计学意义(P<0.001)。B超中筋膜厚度测量法的曲线下面积、敏感度、特异度分别为0.841、64.3%、91.7%,应变比法的曲线下面积、敏感度、特异度分别为0.906、81.0%、83.3%,实时超声弹性图像中评分法的曲线下面积、敏感度、特异度分别为0.861、85.7%、72.9%。结论 RTE可显示足底筋膜炎的筋膜弹性减低,且较B超具有更高的敏感性。 Purpose To investigate the value of real-time elastosonography(RTE)in the diagnosis of plantar fasciitis in patients whose morphological changes in the fascia could not be detected by B-mode ultrasound.Materials and Methods A total of 36 patients with plantar fasciitis(42 feet)and 24 healthy volunteers(48 feet)were enrolled in this study.The maximum thickness of fascia was measured by B-mode ultrasound.The fascia was scored according to corresponding RTE image and the strain rate relative to surrounding soft tissue was calculated.The value of these methods in the diagnosis of plantar fasciitis was compared.Results The fascia thickness,the score of elastic image and the strain ratio in the patient group were higher than those in the control group,with statistically significant differences(P<0.001).The area under the curve,sensitivity,specificity of fascial thickness measurement method using B-mode ultrasound were 0.841,64.3%and 91.7%,respectively;while they were respectively 0.906,81%and 83.3%for strain rate method,and were respectively 0.861,85.7%and 72.9%for elasticity scoring method using RTE.Conclusion RTE can reveal the decrease of fascial elasticity in plantar fasciitis,with higher sensitivity than B-mode ultrasound.
作者 杜丹 晏铮剑 郑元义 DU Dan;YAN Zhengjian;ZHENG Yuanyi(Institute of Ultrasound Imaging,Chongqing Medical University,Chongqing 400010;Department of Ultrasound,the Second Affiliated Hospital of Chongqing Medical University,Chongqing 400010)
出处 《中国医学影像学杂志》 CSCD 北大核心 2018年第8期628-631,共4页 Chinese Journal of Medical Imaging
基金 国家自然科学基金(81425014) 重庆市科委基金(cstc2013jcyjjq10004)
关键词 筋膜炎 足底 超声检查 弹性成像技术 Fasciitis,plantar Ultrasonography Elasticity imaging techniques
  • 相关文献

参考文献2

二级参考文献35

  • 1Li Y, Snedeker JG. Elastography: modality-specific approaches, clinical applications, and research horizons[J]. Skeletal Radiol, 2011, 40(4): 389-397.
  • 2Garra BS. Elastography: current status, future prospects,and making it work for you[J]. Ultrasound Q, 2011, 27(3 ): 177-186.
  • 3Drakonaki EE, Allen GM, Wilson DJ. Ultrasound elastography for musculoskeletal applications[J]. Br J Radiol, 2012, 85(1019): 1435-1445.
  • 4Park GY, Kwon DR. Application of real-time sonoelastography in musculoskeletal diseases related to physical medicine and rehabilitation[J]. Am J Phys Med Rehabil, 2011, 90(11): 875-886.
  • 5Drakonaki EE, Allen GM, Wilson DJ. Real-time ultrasound elastography of the normal Achilles tendon: reproducibility and pattern description[J]. Clin Radiol, 2009, 64(12): 1196-1202.
  • 6De Zordo T, Chhem R, Smekal V, et aL Real-time sonoelastography: findings in patients with symptomatic achilles tendons and comparison to healthy volunteers[J]. Ultraschall Med, 2010, 31 (4): 394-400.
  • 7Turan A, Tufan A, Mercan R, et al. Real-time sonoelastography of Achilles tendon in patients with ankylosing spondylitis[J]. Skeletal Radiol, 2013, 42(8): 1113-1118.
  • 8De Zordo T, Lill SR, Fink C, et al. Real-time sonoelastography of lateral epicondylitis: comparison of findings between patients and healthy volunteers[J]. AJR Am J Roentgenol, 2009, 193(1): 180-185.
  • 9Ahn KS, Kang CH, Hong S J, et al. Ultrasound elastography of lateral epicondylosis:clinical feasibility of quantitative elastographic measurements[J]. AJR Am J Roentgenol, 2014, 202(5): 1094-1099.
  • 10Porta.F, Damjanov.N, Galluccio.F, et al. Ultrasound elastography is a reproducible and feasible tool for the evaluation of the patellar tendon in healthy subjects[J]. Int J Rheum Dis, 2014, 17(7): 762-766.

共引文献26

同被引文献145

引证文献15

二级引证文献41

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部