摘要 为制备大流量气溶胶滤膜标准γ体源,采用参数优化的专用滴源装置,将放射性标准溶液60Co定量滴注在气溶胶取样滤膜上,晾干后对角折叠,并采用专用压样装置压制成与测量样品几何形状一致、密实的圆盘形固态物,密封保存。采用差重法对制备的滤膜标准γ源进行活度定值,制备的气溶胶滤膜标准γ体源活度值为4.4×10^(4 )Bq,相对扩展不确定度U(k=2)为3.6%。采用分割压制法对气溶胶滤膜标准γ体源进行均匀性测量,相对标准偏差低于5%。制备的滤膜标准γ源可为测量大流量气溶胶样品的γ谱仪效率刻度服务。 Determining the activity deposited in aerosol sampling filters in the context of monitoring the environment and their raleases remains a major metrological challenge because of the diversity of filters and their conditions for use.The lack of truly suitable standard filters precludes satisfactorily linking the radioactivity measurement of these filters to a primary reference.The majority of laboratories involved in this type of measurement use soild sources to calibrate their instruments.These sources are not representative of aerosol sampling on a filter.Indeed,the detection efficiency of the instrument is highly influenced by numerous parameters related to aerosol deposits in the filtering medium.To establish the aerosol filter standardγsource for radioactive aerosol monitoring during environmental radiation monitoring,the automatic sampler and pressure mould have been designed and prosessed.In order to make the radioactive material evenly distributed on the filter,the drop parameters which includes radioactive solution components,the drop source spacing and the drop source height have been optimizing,then the radioactive standard solution was quantitatively infused on the aerosol sampling membrance using a dotted drip method.After the filters are dried,the filtes are folded diagonally and pressed through the sample pressing mould,pressed into a compact disc-type which consistent with the geometric shape of the measured sample,sealed.The activity of prepared filter standard source was determined by the amount of radioactive solution added.The results show that the extended uncertainty of aerosol filter standardγsource activity is 3.6%(k=2).The uniformity of the aerosol filter source was measured by spliting and re-pressing.The results show that uniformity of the aerosol filter source is better than 5%.Aerosol filtration standardγsource for calibration of high flow aerosol sampleγspectrometer.This method of aerosol filter source preparation could also be used in the production of secondary standards,whose properties are more adapted to the needs of laboratories measuring radioactivity in filters than are the solid sources that they typically use.
作者 李明 徐利军 宋鑫鹏 肖振红 陈克胜 夏文 LI Ming;XU Lijun;SONG Xinpeng;XIAO Zhenhong;CHEN Kesheng;XIA Wen(National Key Laboratory for Metrology and Calibration Techniques, China Institute of Atomic Energy,Beijing 102413,China)
出处 《同位素》 CAS 2018年第6期370-374,共5页 Journal of Isotopes
关键词 气溶胶 滤膜 标准γ体源 效率刻度 aerosol filter standardγsource calibration
  • 相关文献

参考文献11

二级参考文献83

  • 1张子斌,Adolf.Goetz,韦冠一,李雪松,H.Gerken,常永福.准确分析微量惰性气体的轻便四极杆质谱系统[J].质谱学报,2004,25(B10):203-204. 被引量:4
  • 2刘健.高纯锗γ谱仪对环境样品的效率刻度[J].核动力工程,1994,15(3):267-270. 被引量:5
  • 3沙连茂,卫为强,宣义仁.放射性环境监测中探测限附近测量数据的处理[J].环境监测管理与技术,2006,18(1):38-43. 被引量:18
  • 4国家环境保护总局核安全与辐射环境管理司.HJ/T61-2001辐射环境监测技术规范[S].北京:中国环境科学出版社,2001.
  • 5中华人民共和国卫生部.WS/T184-1999空气中放射性核素的γ能谱分析方法[S].北京:中国标准出版社,1999:1-14.
  • 6中华人民共和国卫生部.GB11713-89用半导体γ谱仪分析低比活度γ放射性样品的标准方法[S].北京:中国标准出版社,1989:1-10.
  • 7KARHU P. Radionuclide monitoring as part of the verification regimefor the comprehensive nuclear-test-ban treaty [ J]. Radio- chemistry, 2001, 43(5) :455 - 457.
  • 8王凤英,周程,张斌,等.电离辐射防护与安全基础知识[M].江苏:江苏人民出版社,2007:12.
  • 9Judge SM, et al. The calibration of large area sources using a gamma-spectrometer[J]. Appl Radiat Isot, 1987, 38(10):865.
  • 10Vesic D, et al. Some practical aspects of gammaray spectroscopy of voluminous cylindrical sources with germanium detectors[J]. Nucl Instrum Methods, 1989, A276:216.

共引文献41

同被引文献83

引证文献4

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部