基于电弧电流边际谱能量比的输电线路永久性故障识别方法 被引量:12

Permanent Fault Identification Method for Transmission Line Based on Marginal Spectral Energy Ratio of Arc Current
下载PDF
导出
摘要 为避免输电线路故障发生之后采用自动重合闸重合于永久性故障后对系统造成危害,在系统故障跳闸后准确判别故障性质以实现自适应重合闸具有重要意义。针对三相交流输电系统,分析了单相接地故障时故障电弧的特性,利用故障发生后的双端电气量推导出电弧电流的特征表达式。通过对该表达式的计算结果序列进行边际谱能量分析,提出了基于电弧电流边际谱能量比的永久性故障识别方法。仿真验证表明,该故障识别方法能够有效可靠地识别永久性故障与瞬时性故障,且不受故障位置、过渡电阻影响。 To avoid harm to the system caused by adaptive reclosing adopted by the transmission line after permanent fault,an accurate identification of fault type after tripping to further realize adaptive reclosing is of significance.For a three-phase AC power transmission system,the characteristics of arc fault under single-phase ground fault are analyzed.The characteristic expressions of arc current after fault are derived based on the double-end electrical quantities.By ana.lyzing the marginal spectrum energy of the sequence of calculation results obtained using this expression,a permanent fault identification method based on marginal spectrum energy ratio of arc current is proposed.Simulation results verify that this fault identification method can effectively and reliably identify permanent faults and transient faults,and it is not affected by the fault location or transition resistance.
作者 李博通 赵盛 李斌 姚斌 李宝伟 LI Botong;ZHAO Sheng;LI Bin;YAO Bin;LI Baowei(School of Electrical and Information Engineering,Tianjin University,Tianjin 300072,China;XJ Group Corporation,Xuchang 461000,China)
出处 《电力系统及其自动化学报》 CSCD 北大核心 2018年第10期61-67,共7页 Proceedings of the CSU-EPSA
基金 国家电网总部科技资助项目"基于全域信息的失灵保护和自适应重合闸技术研究"
关键词 电弧电流特征表达式 故障电弧 永久性故障 瞬时性故障 边际谱能量比 故障识别 characteristic expression of arc current fault arc permanent fault transient fault marginal spectrum en.ergy ratio fault identification
  • 相关文献

参考文献11

二级参考文献114

共引文献350

同被引文献183

引证文献12

二级引证文献43