期刊文献+

Acetabular components with or without screws in total hip arthroplasty 被引量:2

Acetabular components with or without screws in total hip arthroplasty
下载PDF
导出
摘要 AIM To compare the operation time, blood loss, and early outcomes of acetabular components with and without the screw.METHODS Thirty patients who underwent cementless acetabular component with or without screw and whose follow-up exceeded one year period in total hip arthroplasty were evaluated. A posterior approach was used in all surgical procedures by one experienced surgeon. Demographic data, operation time, intra-and postoperative blood loss volume, follow-up clinical score, cup migration, and osteolysis were recorded. The Kolmogorov-Smirnov test was performed for testing the normality of study data. Mann-Whitney U test was used to analyze the intergroup differences. A P-value of ≤ 0.05 was considered statistically significant.RESULTS Acetabular components were used in 16(53.3%) patients with screw and 14(46.7%) without screw. After one year of follow-up, an osteolytic lesion of 3 mm was found in only one patient in the screw group. No cup migrationwas encountered. Intra-group mean Harris hip score significantly increased, but there was no significant intergroup difference. While the mean operation time of the screw group was 121.8 min(range; 95-140), it was 102.7 min(range; 80-120) in the no-screw group, and this difference was statistically significant(P = 0.002). The mean intraoperative/postoperative, and total blood loss were 556.6 mL(range: 350-800)/423.3 mL(range: 250-600), and 983.3 mL(range: 600-1350), respectively in the screw group; and 527 mL(range: 400-700)/456 mL(range: 230-600), and 983 mL(range: 630-1250), respectively in the no-screw group. The blood loss difference between the two groups was not significant. In the screw group, the operation time was 19.1 min longer than the no-screw group, and this difference was statistically significant.CONCLUSION Acetabular components with or without screw have similar results, but the use of screw increases the operation time significantly, while not changing the blood loss volume. AIM To compare the operation time, blood loss, and early outcomes of acetabular components with and without the screw.METHODS Thirty patients who underwent cementless acetabular component with or without screw and whose follow-up exceeded one year period in total hip arthroplasty were evaluated. A posterior approach was used in all surgical procedures by one experienced surgeon. Demographic data, operation time, intra-and postoperative blood loss volume, follow-up clinical score, cup migration, and osteolysis were recorded. The Kolmogorov-Smirnov test was performed for testing the normality of study data. Mann-Whitney U test was used to analyze the intergroup differences. A P-value of ≤ 0.05 was considered statistically significant.RESULTS Acetabular components were used in 16(53.3%) patients with screw and 14(46.7%) without screw. After one year of follow-up, an osteolytic lesion of 3 mm was found in only one patient in the screw group. No cup migrationwas encountered. Intra-group mean Harris hip score significantly increased, but there was no significant intergroup difference. While the mean operation time of the screw group was 121.8 min(range; 95-140), it was 102.7 min(range; 80-120) in the no-screw group, and this difference was statistically significant(P = 0.002). The mean intraoperative/postoperative, and total blood loss were 556.6 mL(range: 350-800)/423.3 mL(range: 250-600), and 983.3 mL(range: 600-1350), respectively in the screw group; and 527 mL(range: 400-700)/456 mL(range: 230-600), and 983 mL(range: 630-1250), respectively in the no-screw group. The blood loss difference between the two groups was not significant. In the screw group, the operation time was 19.1 min longer than the no-screw group, and this difference was statistically significant.CONCLUSION Acetabular components with or without screw have similar results, but the use of screw increases the operation time significantly, while not changing the blood loss volume.
出处 《World Journal of Orthopedics》 2017年第9期705-709,共5页 世界骨科杂志(英文版)
关键词 Hip ARTHROPLASTY ACETABULAR FIXATION With SCREW WITHOUT SCREW Operation time Hip arthroplasty Acetabular fixation With screw Without screw Operation time
  • 相关文献

同被引文献7

引证文献2

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部