期刊文献+

低剂量CT扫描技术联合IMR技术在乳腺癌术前诊断的应用 被引量:7

Application of Low-dose CT Scanning Combined with IMR Technique in Preoperative Diagnosis of Breast Cancer
下载PDF
导出
摘要 目的探讨低剂量CT扫描技术联合迭代模型重建(IMR)技术在乳腺癌术前中的应用。方法选择2014年12月至2017年11月于我院进行乳腺癌手术的患者60例,均进行CT乳腺和胸部扫描,分别采用模型迭代重建(IMR)技术和滤波反射投影重建(FBP)技术进行图像重建,比较两种技术客观图像质量[感兴趣区内CT值、噪声(SD)值、对比噪声比(CNR)]、主观图像质量[病灶轮廓、伪影、噪声、图像清晰度]。结果 IMR技术乳腺病灶感兴趣区内CT值与FBP技术无显著差异(P>0.05),SD值明显低于FBP技术(P<0.05),CNR明显高于FBP技术(P<0.05)。IMR技术乳腺病灶轮廓、伪影、噪声、图像清晰度评分均明显高于FBP技术(P<0.05)。IMR技术胸部伪影、噪声、图像清晰度评分均明显高于FBP技术(P<0.05)。CT扫描总剂量为(5.21±1.06)mGy,总ED为(2.20±0.41)mSy;乳腺动态扫描总剂量为(1.68±0.49)mGy,ED为(0.63±0.19)mSy。结论低剂量CT扫描技术联合IMR技术具有较好图像质量,对乳腺癌术前评估具有重要临床价值。 Objective To explore the application of low-dose CT scanning combined with iterative model reconstruction(IMR)technique in preoperative diagnosis of breast cancer.Methods A total of 60 cases of breast cancer in our hospital from December 2014 to November 2017 were selected and given CT scanning of breast and chest.Image reconstruction was carried out by using iterative model reconstruction(IMR)and filtered back-projection reconstruction(FBP)respectively.The objective image quality[CT value,noise(SD)value and contrast noise ratio(CNR)of regions of interest]and subjective image quality[lesion contour,artifact,noise and image definition]were compared between the two technologies.Results There was no significant difference in the CT value of breast regions of interest between the IMR technique and the FBP technique(P >0.05),and the SD value was significantly lower than that of the FBP technique(P<0.05)while the CNR was significantly higher than that of the FBP technique(P<0.05).The scores of lesion contour,artifact,noise and image definition of breast by the IMR technique were significantly higher than those by the FBP technique(P<0.05).The scores of artifact,noise and image definition of chest by the IMR technique were significantly higher than those by the FBP technique(P<0.05).The total dose of CT scanning was(5.21±1.06)mGy,and the total ED was(2.20±0.41)mSy.The total dose of breast dynamic scan was(1.68±0.49)mGy,and the ED was(0.63±0.19)mSy.Conclusion Low-dose CT scanning combined with IMR technique has good image quality and has important clinical value in preoperative assessment of breast cancer.
作者 王天义 WANG Tian-yi(Department of Surgery,Jiaozuo Maternal and Child Health Hospital,Jiaozuo 454000,Henan Province,China)
出处 《中国CT和MRI杂志》 2019年第2期9-11,共3页 Chinese Journal of CT and MRI
关键词 低剂量CT 迭代模型重建 乳腺癌 图像质量 Low-dose CT Scanning Iterative Model Reconstruction Breast Cancer Image Quality
  • 相关文献

参考文献10

二级参考文献83

  • 1卢晓玲,杨振燕,王培军.多层螺旋CT的重建方法对乳腺肿块的显示及诊断价值[J].同济大学学报(医学版),2005,26(5):54-57. 被引量:1
  • 2刘鹏,刘艳,孙慧.小鼠乳腺癌中p53与bcl-2/bax基因表达的相关性研究[J].中华实验外科杂志,2007,24(2):176-178. 被引量:11
  • 3BOLL D T, HOFFMANN M H, HUBER N, et al. Spectral coronary multidetector computed tomography angiography: dual benefit by facilitating plaque characterization and enhancing lumen depiction[J]. J Comput Assist Tomogr, 2006, 30(5): 804-811.
  • 4CHENG Z, WANG X, DUAN Y, et al. Ix~w-dose prospective ECG-triggering dual-source CT angiography in infants and children with complex congenital heart disease: first experience [J]. Eur Radiol, 2010, 20(10): 2503-2511.
  • 5BULLA S, BLANKE P, HASSEPASS F, et al. Reducing the radiation dose for low-dose CT of the paranasal sinuses using iterative reconstruction: Feasibility and image quality[J]. Eur J Radiol, 2012,81 ( 9 ) : 2246-2250.
  • 6PAUL J F, ROHNEAN A, ELFASSY E, et al. Radiation dose for thoracic and coronary step-and-shoot CT using a 128-slice dual-source machine in infants and small children with congenital heart disease [J]. Pediatr Radiol, 2011, 41 (2) : 244-249.
  • 7TSAIIC, CHENM C, JAN S L, et al multidetector row CT: why and how we do it[J] 2008, 38(4) : 438-451.
  • 8Neonatal cardiac Pediatr Radiol, HUANG M P, LIANG C H, ZHAO Z J, et al. Evaluation of image quality and radiation dose at prospective ECG-triggered axial 256-slice multi-detector CT in infants with congenital heart disease [ J ]. Pediatr Radiol, 2011, 41 (7) : 858-866.
  • 9LEIPSIC J, LABOUNTY T M, HEILBRUN B, et al. Adaptive statistical iterative reconstruction: assessment of image noise and image quality in coronary CT angiography [ J ]. AJR Am J Roentgenol, 2010, 195(3) : 649-654.
  • 10HARA A K, PADEN R G, SILVA A C, et al. Iterative reconstruction technique for reducing body radiation dose at CT: feasibility study [J]. AIR Am J Roentgenol, 2009, 193 (3) : 764-771.

共引文献152

同被引文献39

引证文献7

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部