为探讨地铁站火灾烟气的扩散规律,使用火灾动力学模拟软件(FDS)对广州大学城北地铁站站台进行了火灾烟气扩散规律研究。根据地铁站内的实测温度、风速等数据确定了数值模拟所需的边界条件,运用湍流大涡模拟方法和信息传递接口(MPI)对地铁站台进行了实景模拟。结果表明:当站台中央发生火灾时,左侧烟气浓度比右侧高约133%,一氧化碳浓度比右侧高约75%,温度比右侧高约41%;相比之下,站台右侧更适合人员逃生。
To investigate the flow regularity of smoke in the subway station,Fire Dynamics Simulator is used to study the fire smoke spread in the Higher Education Mega Center North Station.The boundary conditions required for numerical simulation are determined based on the measured temperature and air velocity in the subway station.Large Eddy Simulation(LES)and Massive Passage Interface(MPI)are used to do realistic view simulation of the subway platform.As the result shows,when a fire breaks out in the middle of the platform,smoke concentration,CO concentration and temperature on the left part of the platform are about 133 percent,75 percent and 41 percent respectively higher than those on the right part.Therefore,the right part of the platform is more secure for personnel evacuation.
作者
陈柯成
谢嘉斌
姚清河
CHEN Kecheng;XIE Jiabin;YAO Qinghe(School of Aeronautics and Astronautics,Sun Yat-sen University,Guangzhou 510006,China)
出处
《中山大学学报(自然科学版)》
CAS
CSCD
北大核心
2019年第2期15-22,共8页
Acta Scientiarum Naturalium Universitatis Sunyatseni
基金
大学生创新训练计划项目(201701076)
NSFC-广东联合基金(第三期
NSFC2015_582)超级计算科学应用研究
关键词
站台火灾
数值模拟
逃生策略
烟气扩散
subway platform fire
numerical simulation
evacuation strategy
smoke spread