期刊文献+

安装条件对超声流量计计量准确性影响初探 被引量:1

Preliminary Study on Influence of Installation Conditions on Measuring Accuracy of Ultrasonic Flowmeters
下载PDF
导出
摘要 采用实验测试与数值模拟相结合的方式,研究了不同安装条件对超声流量计计量准确性的影响。实验结果表明锈蚀直管段及是否安装整流器以及安装哪种整流器对流态及计量结果有较大影响,数值模拟结果佐证了实验结果。为保证贸易交接准确可靠,超声流量计检定和现场使用安装条件应符合标准要求,若不能做到一致时,建议一并送检流量计配套附件。 The effects of different installation conditions on measuring accuracy of ultrasonic flowmeter were studied by means of experimental test and numerical simulation. The experimental results show that the rusted straight pipe section and whether or not to install flow conditioner and which flow conditioner to install have a great influence on the flow state and measurement results. The numerical simulation results support the experimental results. In order to ensure the accuracy and reliability of the trade handover, the verification and on-site use and installation should meet the standard requirements. If the consistency cannot be achieved, it is suggested to submit the supporting accessories of the flow meter for inspection together.
作者 韩巍 陈行川 张火箭 王多才 周雷 HAN Wei;CHEN Xing-chuan;ZHANG Huo-jian;WANG Duo-cai;ZHOU Lei(Petrochina West East Gas Pipeline Nanjing Measurement Testing Center, Nanjing, Jiangsu 210058, China)
出处 《计量学报》 CSCD 北大核心 2018年第B12期88-92,共5页 Acta Metrologica Sinica
关键词 计量学 计量准确性 数值模拟 超声流量计 安装条件 整流器 metrology metering accuracy numerical simulation ultrasonic flowmeters installation condition flow conditioner
  • 相关文献

参考文献5

二级参考文献26

  • 1杨鼎南.多路超声波气体流量计[J].国外油气储运,1993,11(2):34-39. 被引量:4
  • 2张福元.AGA8方程计算天然气压缩因子[J].石油工业技术监督,1994(5):16-18. 被引量:7
  • 3王勇.多波束超声波气体流量计计量技术[J].天然气与石油,1994,12(3):45-49. 被引量:7
  • 4Transmission Measurement Committee. Measurement of gas by multipath ultrasonic meters [S]. Washington, D. C.. American Gas Association, 1998.
  • 5WALSH J T. A report of acoustic transit time accuracy field work performed in North America [C]//The 5th International Conference on Hydraulic Efficiency Measurements, Luceme, Switzerland, 2004: 21-29.
  • 6DRENTHEN J G, BOER G. The manufacturing of ultrasonic gas flow meters [J]. Flow Measurement and Instrumentation, 2001, 12.- 89-99.
  • 7WALSH J T. ASME PTC 18-2002 Hydraulic turbines and pump-turbines[S]. New York: ASME, 2002.
  • 8VOSER A. CFD-Calculations of the protrusion effect and impact on the acoustic discharge measurement accuracy[DB/OL]. (1996-06-28)[2010-08-30]. http: //www. ighem.org/Paper 1996/IGHEM 1996_35.pdf.
  • 9LOWELL F, SCHAFER S, WALSH J. Acoustic flowmeters in circular pipes: Acoustic transducer and conduit protrusion effects in discharge measurement [DB/OL]. (1998-08-20)[2010-08-30]. http://www.ighem.org/ Paper 1998flQHEM 1998_05.pdf.
  • 10RENALDAS R. Investigation of the flow velocity profile in a metering section of an invasive ultrasonic flowmeter [J]. Flow Measurement and Instrumentation, 2006, 17: 201-206.

共引文献68