期刊文献+

Evaluation of copper removal efficiency using water treatment sludge 被引量:2

Evaluation of copper removal efficiency using water treatment sludge
下载PDF
导出
摘要 Large quantities of sludge are produced during water treatment processes. Recently, sludge has been treated as waste and disposed of in landfills, which increases the environmental burdens and the operational cost. Therefore, sludge reuse has become a significant environmental issue. In this study, adsorption of copper ions (Cu^2+) onto calcined sludge was investigated under various operational conditions (with varying temperature, Cu^2+ initial concentration, pH, and sludge dosage). The prepared sludge material was characterized with transmission electron microscopy (TEM), X-ray diffraction (XRD), dynamic light scattering (DLS), and Brunauer-Emmett-Teller (BET) surface area. The sorption capacity of sludge was directly proportional to the initial Cu^2+ concentration and inversely proportional to the sludge dosage. The optimum operational pH and solution temperature were 6.6 and 80℃, respectively. The experimental results followed a Langmuir isotherm and pseudo-first-order adsorption kinetics. Thermodynamic parameters such as activation energy, change in free energy, enthalpy, and entropy were calculated. Thermodynamic analyses indicated that the sorption of copper ions onto the calcined sludge was driven by a physical adsorption process. The prepared sludge was proven to be an excellent adsorbent material for the removal of Cu^2+ from an aqueous solution under optimum conditions. Large quantities of sludge are produced during water treatment processes. Recently, sludge has been treated as waste and disposed of in landfills,which increases the environmental burdens and the operational cost. Therefore, sludge reuse has become a significant environmental issue. In this study, adsorption of copper ions(Cu2+) onto calcined sludge was investigated under various operational conditions(with varying temperature, Cu2+initial concentration, pH, and sludge dosage). The prepared sludge material was characterized with transmission electron microscopy(TEM), X-ray diffraction(XRD), dynamic light scattering(DLS), and Brunauer-Emmett-Teller(BET) surface area. The sorption capacity of sludge was directly proportional to the initial Cu2+ concentration and inversely proportional to the sludge dosage. The optimum operational pH and solution temperature were 6.6 and 80℃, respectively. The experimental results followed a Langmuir isotherm and pseudo-first-order adsorption kinetics.Thermodynamic parameters such as activation energy, change in free energy, enthalpy, and entropy were calculated. Thermodynamic analyses indicated that the sorption of copper ions onto the calcined sludge was driven by a physical adsorption process. The prepared sludge was proven to be an excellent adsorbent material for the removal of Cu2+ from an aqueous solution under optimum conditions.
出处 《Water Science and Engineering》 EI CAS CSCD 2019年第1期37-44,共8页 水科学与水工程(英文版)
关键词 Copper REMOVAL ADSORPTION SLUDGE Water treatment PLANT OPERATIONAL conditions Copper removal Adsorption Sludge Water treatment plant Operational conditions
  • 相关文献

参考文献2

二级参考文献2

共引文献15

同被引文献14

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部