摘要
本文采用Fluent软件对毛细管网顶板传热性能进行模拟数值分析,通过建立毛细管网三维流固传热模型,研究在夏季工况下不同因素对辐射顶板的传热性能的影响情况,通过从不同影响因素中所得出的温度场及相关供冷量进行分析,为以后的工程设计提供一定的参考依据。
Heat transfer performance of capillary top plate was analyzed by Fluent software. A three-dimensional fluid-solid heat transfer model of capillary network is established to study the effect of different factors on the heat transfer performance of the radiation roof during summer conditions. The analysis of the temperature field and related cooling capacity obtained from different influencing factors to provide a certain reference for future engineering design.
作者
侯波
梁珍
HOU Bo;LIANG Zhen(School of Environmental Science and Engineering, Donghua University)
出处
《建筑热能通风空调》
2019年第4期14-17,共4页
Building Energy & Environment
关键词
毛细管网
温度场
数值模拟
供冷量
capillary network
temperature field
numerical simulation
cooling capacity