摘要
本文结合当前数据中心已有制冷系统模式和学术研究现状,对数据中心典型制冷系统的优缺点及技术特征进行了对比,并结合广州某数据中心工程实例重点介绍了液/气双通道制冷系统构成及其节能效果,为其他类似项目制冷系统建设提供设计思考。
Combining the current model of data center refrigeration system,the advantages and disadvantages and technical characteristics of a data center typical refrigeration system was compared,and a data center project of Guangzhou was included focus on liquid/gas dual channel refrigeration system and its energy saving effect. It will provide suggest for other similar project construction.
作者
伍晓峰
WU Xiao-feng(Shenzhen General Institute of Architectural Design and Research Co.,Ltd.)
出处
《建筑热能通风空调》
2019年第6期33-35,6,共4页
Building Energy & Environment
关键词
数据中心
芯片液冷
节能
双通道制冷
data center
chip liquid cooling
energy conservation
double channel refrigeration