期刊文献+

超声断层显像技术诊断胎儿主动脉弓畸形 被引量:10

Prenatal diagnosis of aortic arch malformation using tomographic ultrasound imaging
下载PDF
导出
摘要 目的探讨时空影像关联(STIC)技术结合超声断层显像(TUI)诊断胎儿主动脉弓异常的价值。方法回顾性分析45胎主动脉弓畸形胎儿的产前超声资料。以二维超声心动图(2DE)于三血管-气管切面判断主动脉弓相对于气管的位置,寻找异常头臂动脉。以STIC技术采集容积数据后,分别在横断面及冠状面行TUI重建,于横断面TUI切面判断弓的位置;于冠状面TUI切面寻找迷走左、右锁骨下动脉及双侧主动脉弓汇合处。结果45胎中,5胎双主动脉弓,9胎左位主动脉弓合并右锁骨下动脉迷走,31胎右位主动脉弓。STIC-TUI法及2DE对胎儿主动脉弓畸形的诊断率分别为97.78%(44/45)及71.11%(32/45),差异有统计学意义(P<0.01)。结论STIC-TUI法可准确诊断胎儿主动脉弓畸形;标准化容积数据后处理方法使临床推广成为可能。 Objective To explore the value of spatio-temporal image correlation (STIC) with tomographic ultrasound imaging (TUI) technique in diagnosis of fetal aortic arch malformation.Methods Ultrasonic data of 45 fetuses diagnosed as aortic arch malformation were reviewed retrospectively.Three-vessel and trachea view of 2D echocardiography (2DE) were used to analyze the aortic arch position in relation to the trachea,and to find the aberrant brachiocephalic arteries.Volume data were obtained,and TUI reconstruction was used to form transverse and coronal TUI slices to observe the arch position,the aberrant left or right subclavian arteries,the origin and convergence of bilateral aortic arches.Results Totally 5 fetuses of double aortic arch,9 fetuses of left aortic arch with aberrant right subclavian arteries and 31 fetuses of right aortic arch were included.The accuracy rate of STIC-TUI in diagnosis of fetal aortic arch anomalies was significantly higher than that of 2DE (97.78%[44/45] vs 71.11%[32/45];P <0.01).Conclusion Fetal aortic arch malformation can be accurately diagnosed using STIC-TUI,which can be widely used with standardized post-analysis in the future.
作者 齐禹 王彧 张颖 QI Yu;WANG Yu;ZHANG Ying(Department of Ultrasound,Shengjing Hospital of China Medical University,Shenyang 110004,China)
出处 《中国医学影像技术》 CSCD 北大核心 2019年第9期1305-1309,共5页 Chinese Journal of Medical Imaging Technology
基金 辽宁省科学技术项目(2012225098) 沈阳市科学技术项目(F16-206-9-11)
关键词 胎儿 心脏 主动脉弓异常 超声检查 产前 超声断层显像 fetus heart aortic arch malformation ultrasonography,prenatal tomographic ultrasound imaging
  • 相关文献

参考文献9

二级参考文献54

  • 1刘涛,吴瑛.实时三维超声:胎儿心脏成像的新视窗[J].中国医学影像技术,2007,23(1):151-153. 被引量:24
  • 2Vinals F,Poblete P,Giuliano A.Spatio-temporal image correlation (STIC):a new tool for the prenatal screening of congenital heart defects.Ultrasound Obstet Gynecol,2003,22(4):388-394.
  • 3Chaoui R,Hoffmann J,Heling KS.Three-dimensional (3D) and 4D color Doppler fetal echocardiography using spatio-temporal image correlation (STIC).Ultrasound Obstet Gynecol,2004,23(6):535-545.
  • 4Devore GR,Falkensammer P,Sklansky MS,et al.Spatio-temporal image correlation (STIC):new technology for evaluation of the fetal heart.Ultrasound Obstet Gynecol,2003,22(4):380-387.
  • 5Abuhamad A,Falkensammer P,Zhao Y.Automated sonography:defining the spatial relationship of standard diagnostic fetal cardiac planes in the second trimester of pregnancy.J Ultrasound Med,2007,26(4):501-507.
  • 6Zhang D,Zhang Y, Ren W, et al.Prenatal diagnosis of fetal inter- rupted aortic arch type A by two-dimensional echocardiography and four - dimensional echocardiography with B-flow imaging and spatio- temporal image correlation[J].Echocardiography, 2016, 33(1):90-98.
  • 7Vinals F, Mandujano L, Vargas G, et al.Prenatal diagnosis of con- genital heart disease using four-dimensional spatio-temporal image correlation (STIC)telemedicine via an internet link: a pilot study[J].Ultrasound Obstet Gynecol,2005,25(1):25-31.
  • 8Goncalves LF, Lee W, Espinoza J, et al.Examination of the fetal heart by four-dimensional (4D)ultrasound with spatio-temporal im- age correlation CSTIC)[J].Ultrasound Obstet Gynecol, 2006, 27(3):336-348.
  • 9Yagel S,Cohen SM,Shapiro I,et al.3D and 4D ultrasound in fetal cardiac scanning: a new look at the fetal heart[J], Ultrasound Ob- Stet Gynecol,2007,29(1):81-95.
  • 10Zhang Y,Cai A,Sun W,et al.Prenatal diagnosis of fetal congenital- ly corrected transposition of the great arteries[J].Prenat Diagn, 2011,31(6):529-535.

共引文献53

同被引文献103

引证文献10

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部