自体心包主动脉瓣重建术在主动脉瓣狭窄病变的临床应用 被引量:6

Clinical study of autologous pericardial aortic valve reconstruction in aortic valve stenosis
下载PDF
导出
摘要 目的探讨运用自体心包主动脉瓣重建术治疗主动脉瓣狭窄病变的疗效。方法2017年10月至2019年6月,对15例主动脉瓣狭窄病变采取了自体心包主动脉瓣重建术治疗。术后观察主动脉瓣跨瓣压、主动脉瓣跨瓣流速、主动脉瓣返流、左心室大小情况。结果术前平均主动脉瓣跨瓣压为(75.2±26.4)mmHg、平均主动脉跨瓣流速(427.9±90.1)cm/s,术后1周、3、6个月平均主动脉瓣跨瓣压降低至分别(13.5±6.0)、(11±3.5)、(10±2.0)mmHg,而术后平均主动脉瓣跨瓣流速降至(169.3±48)、(160.5±60.1)、(145±15.2)cm/s,左心室较前明显缩小,无明显主动瓣返流。结论自体心包主动脉瓣重建术使主动脉瓣有良好的开放及关闭性从而具有良好血液流动学效应,其近中期结果是优良的。 Objective To investigate the therapeutic effect of autologous pericardial aortic valve recon-struction on aortic valve stenosis.Methods From October 2017 to June 2019,15 cases of aortic stenosis were treated with autocardiac aortic valve reconstruction.Postoperative observation of aortic valve across valve pressure,aortic valve across valve blood flow,aortic valve regurgitation,left ventricular size.Results The preoperative average aortic valve cross-valve pressure was(75.2±26.4)mmHg,and the average aortic cross-valve flow was(427.9±90.1)cm/s.After 1 week,3 months,and 6 months,the average aortic valve cross-valve pressure was reduced to(13.5±6.0)、(11±3.5)、(10±2.0)mmHg,respectively.After surgery,the average aortic valve flow rate decreased to(169.3±48)、(160.5±60.1)、(145±15.2)cm/s,left ventricle was significantly reduced and there was no significant active valve regurgitation.Conclusion Autocardio aortic valve reconstruction has a good open and closed aortic valve and thus has a good blood flow effect.The results in the near term are excellent.
作者 陈文 刘永春 郑晓宇 叶世高 石俊杰 CHEN Wen;LIU Yongchun;ZHENG Xiaoyu;YE Shigao;SHI Junjie(Department of Thoracicic and Cardiovascular Surgery,the First Hospital of Nanning,Nanning 530022,China)
出处 《实用医学杂志》 CAS 北大核心 2019年第17期2828-2830,共3页 The Journal of Practical Medicine
关键词 主动脉瓣修复术 主动脉瓣置换术 自体心包主动脉瓣重建术 aortic valve repair aortic valve replacement autopericardial aortic valve reconstruction
  • 相关文献

参考文献3

二级参考文献40

  • 1侯晓彤,孟旭,李伟,王坚刚.左心系统瓣膜替换术后远期三尖瓣关闭不全的手术治疗效果[J].中华医学杂志,2005,85(47):3362-3364. 被引量:11
  • 2刁明强,董力,江虹,周静,肖锡俊,张尔永.心脏机械瓣膜置换术后早期抗凝的方法分析[J].中国胸心血管外科临床杂志,2006,13(1):10-13. 被引量:23
  • 3Pereira JI, Lager MS, Bashir M, et al. Survival after aortic valve replacement for severe aortic stenosis with low transvalvular gradients and severe left ventricular dysfunction. Am Coil Cardiol, 2002, 39(8): 1356-1363.
  • 4Dumesnil IG, Pibarot P. Prevention of moderate prosthesis-patient mismatch: Individualization vs generalization. Rev Esp Cardiol, 2010, 63(4): 387-389.
  • 5Vicchio M, Delia A, De M, et al. Prosthesis-patient mismatch in the elderly:survival, ventricular mass regression, and quality of life. Ann Thorac Sure. 2008. 86(6): 1791 - 1797.
  • 6Brownd JM, O'Brien SM, Wu C, et al. Isolated aortic valve replacement in North America comprising 108, 687 patients in 10 years: changes in risks, valve types, and outcomes in the society of thoracic surgeons national database.Thorac Cardiovasc Surg, 2009(1): 82-90.
  • 7Mohty D, Dmnesnil JG, Echahidi N, et al. Impact of prosthesis- patient mismatch on long-term survival after aortic valve replacement: influence of age, obesityand left ventrieular dysflmction. J Am Coil Cardiol, 2009, 53(2): 39-47.
  • 8Moon MR, Pasque MK, Munfakh NA, et al. Prosthesis-patient mismatch after aortic valve replacement: Impact on age and body size on late survival. Ann Thorac Surg, 2006, 81(2): 481-489.
  • 9Pibarot P, Dumesnil JG.Prosthesis-patient mismatch: definition, clinical impact, and prevention.Heart, 2006, 92(8):1022-1029.
  • 10Tasca G, Mhagna Z, Perotti S, et al. Impact of patient-prosthesis mismatch on cardiac events and midterm mortality after aortic valve replacement in patients with pure aortic stenosis. Circulation, 2006, 113(4): 570-576.

共引文献5

同被引文献34

引证文献6

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部