摘要 讨论流量仪表在应用中常见失误情况 ,包括操作不善和流动扰动及不良安装 ;产生气穴和液体中会有气泡 ;气体中含有冷凝液 ;磨损和沉积等等。这些失误常导致流量仪表测量不准或失灵。 The common failures such as mis installation, cavitation, air bubble in liquid, depositing/scaling and abrasion, and its causes are discussed. Some misunderstandings in the case of normal operation are also explained.
作者 蔡武昌
出处 《石油化工自动化》 CAS 2002年第5期71-74,84,共5页 Automation in Petro-chemical Industry
关键词 流量仪表 应用 操作失误 flowmeters application techniques operation failure
  • 相关文献

参考文献2

二级参考文献2

同被引文献8

  • 1刘永峰,张幽彤,裴普成.天然气发动机汽车的优势和发展现状[J].现代化工,2006,26(z2):395-397. 被引量:12
  • 2K. Kolahi, Th. Cast, and H. Rock, Coriolis mass flow measurement of gas under normal conditions [J]. Flow Measurment and Instrumentation, 1994, 5(4): 275-283.
  • 3Keita N M. The zero drift effect in coriolis mass flowmeters [A]. in Prec. Int. Conf. Mass Flow Measurement Direct & Indirect, London, U.K., Feb. 21 - 22, 1989, pp. 1 - 10.
  • 4J. Hemp, J. Kutin. Theory of errors in Coriolis flowmeter readings due to compressibility of the fluid being metered[J]. Flow Measunnent and Instrumentation 2006,17: 359-368.
  • 5J. Kutin, G. Bobovnik, J. Hemp, I. Bajsic. Velocity profile effects in Coriolis mass flowmeters: Recent findings and open questions [J]. Flow Measurment and Instrumentation, 2006, 17: 349-358.
  • 6Keita NM. Behaviour of straight pipe Coriolis mass flowmeters in the metering of gas: Theoretical predictions with experimental verification [J]. Flow Measurment and Instrumentation, 1994, 5:289 - 294.
  • 7张宇红.天然气 (CNG)加气机的研制[J].矿业安全与环保,2001,28(2):6-7. 被引量:1
  • 8侯毅,施文康,迟颖.科里奥利质量流量计的原理及其误差分析[J].自动化仪表,2001,22(9):18-19. 被引量:12