期刊文献+

油油套管变压器铁心剩磁检测与励磁涌流评估决策研究

Core Remaining Magnetization Detection and Inrush Current Evaluation of Oil Casing Transformer
下载PDF
导出
摘要 本文介绍了油油套管出线变压器铁心剩磁检测原理和接线方式,以一台110kV变压器为应用案例,评估了消磁前后变压器励磁涌流水平,验证了剩磁检测与消磁方法的有效性。 This paper introduced the principle and wiring method of residual magnetism detection for core of oil bushing outlet transformer. Taking a 110 kV transformer as an application case, the inrush current level of transformer before and after demagnetization was evaluated, and the effectiveness of residual magnetism detection and demagnetization method was verified.
作者 朱旭亮 何金 胡振彬 王伟 ZHU Xuliang;HE Jin;HU Zhenbin;WANG Wei(State Grid Tianjin Electric Power Company Electric Power Research Institute,Tianjin 300384;State Grid Shandong Electric Power Company Licheng District Power Supply Company of Jinan City,Jinan Shandong 250100)
出处 《河南科技》 2019年第14期69-71,共3页 Henan Science and Technology
基金 国家电网公司科技项目“基于人工智能的变电检修知识导航与决策优化技术研究及应用”(5200-201918255A-0-0-00)资助
关键词 油油套管 变压器 剩磁 励磁涌流 oil casing transformer remaining magnetism inrush current
  • 相关文献

参考文献4

二级参考文献34

共引文献61

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部