对Stamicarbon2000+CO2汽提工艺中池式反应器低压侧隔板腐蚀问题进行了剖析,指出池式反应器的管侧隔板的设计缺陷,探讨解决办法及相应预防措施。
This paper analyzes the corrosion problem of low pressure side diaphragm plate of the pool reactor in Stamicarbon2000+CO2 stripping process,points out the design defect of the pipe side diaphragm plate of the pool reactor,discusses the solution and corresponding preventive measures.