摘要
文中基于一起直线水滑梯在结束端的伤人事件,结合相关标准条款对截留区要求的变化历程,通过现场测试数据及监控录像的分析,阐述现行标准要求的不足,提出设计及使用过程的整改措施或注意事项,期以降低该类安全隐患的有效控制。
Based on a personal injury incident in slide’s catch unit,combined with the change process of the requirements of relevant standard clauses on the interception area,through the analysis of field test data and monitoring video,this paper expounds the shortcomings of the current standard requirements,puts forward the rectification measures or precautions in the design and use process,in order to reduce the effective control of such safety hazards.
作者
李志毅
LI Zhi-Yi(Fujian Special Equipment Inspection and Research Institute,Fuzhou 350008,Fujian,China)
出处
《质量技术监督研究》
2019年第5期5-8,共4页