摘要 研究了在工业X射线成像领域,放大倍数、管电压、管电流、曝光时间等参数与图像质量的相关性,探讨了图像质量最优时成像参数的选取。试验结果表明:在不考虑有效剂量的前提下,采用高放大倍数、低管电压、大电流,可以获得更好的图像质量。 The relationship between magnification ratio,tube voltage,tube current and exposure time and image quality is studied.The selection of imaging parameters for image quality optimization is explored.The results show that high magnification,low tube voltage and high current can obtain better image quality under the contition of being without considering effective dose.
作者 陈旭 孙晋川 魏存峰 刘宝东 魏龙 CHEN Xu;SUN Jinchuan;WEI Cunfeng;LIU Baodong;WEI Long(Beijing Engineering Research Center of Radiographic Techniques and Equipment,Institute of HighEnergy Physics,Chinese Academy of Sciences,Beijing 100049,China;School of Nuclear Science and Technology,University of Chinese Academy of Sciences,Beijing 100049,China;Lanzhou Institute of Physics,Chinese Academy of Space Technology,Lanzhou 730000,China)
出处 《无损检测》 2019年第10期6-9,14,共5页 Nondestructive Testing
基金 国家重点研发计划资助项目(2017YFF0107201)
关键词 数字X射线成像 图像质量 影响因素 成像参数 digital radiography image quality affecting factor imaging parameter