摘要 电气设备处在电场及高电压的环境中,容易使绝缘性能不断下降,造成设备损坏。为提前消除这个隐患,可以使用局部放电带电检测技术判定设备绝缘状态。本文介绍了局部放电带电检测技术的两种检测方法,并与其他状态检测方法进行对比,详细分析了检测中需要避开的干扰因素。并介绍了局部放电带电检测技术在仪化公司的具体应用情况。 Electrical equipment is in the environment of electric field and high voltage.It is easy to make the insulation performance decline continuously,which may cause equipment damage.In order to eliminate this hidden danger in advance,partial discharge on-line detection technology can be used to determine the insulation status of equipment.In this paper,two detection methods of partial discharge on-line detection technology were introduced.And we compared it with other state detection methods.The interference factors that need to be avoided in the detection were analyzed in detail.The application of partial discharge on-line detection technology in Yihua Company was introduced in detail.
作者 顾达炜 Gu Dawei(Sinopec Yizheng Chemical Fibre Co., Ltd., Yizheng Jiangsu 211900)
出处 《合成技术及应用》 2019年第4期45-47,共3页 Synthetic Technology & Application
关键词 变电站 局部放电带电检测 暂态对地电压检测法 超声波检测法 干扰 transformer substation on-line detection of partial discharge TEV UT interfere
  • 相关文献

参考文献3

二级参考文献23

  • 1宋杲,崔景春,袁大陆.2004年高压开关设备运行统计分析[J].电力设备,2006,7(2):10-14. 被引量:46
  • 2印华,王勇,王谦.12 kV开关柜内部放电的分析与处理[J].高压电器,2006,42(5):395-396. 被引量:20
  • 3王晓哲,李知秋,姚良忠,Christian Sasse,黄瑜珑,曾嵘.开关柜监控采用无线通信的抗干扰性能试验研究[J].高压电器,2007,43(1):18-20. 被引量:11
  • 4王小华,荣命哲,徐铁军,蔡彬,张杭,郭媛媛,王鑫.中压开关柜在线监测系统硬件抗电磁干扰技术研究[J].高压电器,2007,43(5):321-324. 被引量:18
  • 5DU Lin,JIANG Lei,LI Fu-qi.On-line partial discharge monitoring and diagnostic system for power transiormer[J]. Journal of Tsinghua University(Science and Technology), 2005,5(10):598-604.
  • 6CULLEN G,STEWART B G,HEPBURN D M.Application of a radio frequency antenna technique for monitoring the speed,torque and internal fault conditions of AC and DC electric motors[C]//IEEE Proceedings of the ISA/IEEE Sensors for Industry Conference.New Orleans,USA:ISA/ IEEE,2004:50-54.
  • 7BIRLASEKARAN S,WENG H L Comparison of known PD signals with the developed and commercial HFCT sensors[J].IEEE Transactions on Power Delivery,2007,22 (3):1581-1590.
  • 8HONG T.FANG M T CHILDER D.PD classification by a modular neural network based on task decomposition[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 1996,3(2):207-212.
  • 9SONG Xiao-di,ZHOU Cheng-ke,HEPBURN D M.An algorithm for identifying the arrival time of PD pulses for PD source location[C]//IEEE Conference on Electrical Insulation and Dielectric Phenomena.Quebec City,Canada: IEEE,2008:31-34.
  • 10BEFENGER J P.A perfectly matched layer for the absorption of electromagn eticwaves[J].J.Compute.Phys., 1994,114(2):185-200.

共引文献44

同被引文献47

引证文献6

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部