摘要
电气设备处在电场及高电压的环境中,容易使绝缘性能不断下降,造成设备损坏。为提前消除这个隐患,可以使用局部放电带电检测技术判定设备绝缘状态。本文介绍了局部放电带电检测技术的两种检测方法,并与其他状态检测方法进行对比,详细分析了检测中需要避开的干扰因素。并介绍了局部放电带电检测技术在仪化公司的具体应用情况。
Electrical equipment is in the environment of electric field and high voltage.It is easy to make the insulation performance decline continuously,which may cause equipment damage.In order to eliminate this hidden danger in advance,partial discharge on-line detection technology can be used to determine the insulation status of equipment.In this paper,two detection methods of partial discharge on-line detection technology were introduced.And we compared it with other state detection methods.The interference factors that need to be avoided in the detection were analyzed in detail.The application of partial discharge on-line detection technology in Yihua Company was introduced in detail.
作者
顾达炜
Gu Dawei(Sinopec Yizheng Chemical Fibre Co., Ltd., Yizheng Jiangsu 211900)
出处
《合成技术及应用》
2019年第4期45-47,共3页
Synthetic Technology & Application