期刊文献+

TORRENT法混凝土空气渗透系数与其他耐久性指标的量化关系 被引量:5

Establishing quantitative relation betw een concrete air permeability tested by TORRENT method and other indexes of concrete durability
下载PDF
导出
摘要 TORRENT法是一种可以同时测试混凝土试块及混凝土实体结构空气渗透系数的无损检测方法。设计不同强度等级的混凝土,分别测试对应的抗压强度、氯离子扩散系数、电通量以及空气渗透系数。最终建立了空气渗透系数与氯离子扩散系数、电通量之间的量化关系,进而可以用一种无损的检测方式快速评估混凝土实体结构的抗渗性。 TORRENT method is a new kind nondestructive method for testing the concrete air permeability of concrete block in laboratory and concrete structure.Concrete blocks of different strength grade were vibrated,and their compressive strength,diffusion coefficient of chloride ion,electric flux and air permeability were tested.Then,the quantitative relation between concrete air permeability tested by TORRENT method and diffusion coefficient of chloride ion,electric flux was established,respectively.
作者 梁冠亭 谢德擎 石亮站 何文杰 LIANG Guanting;XIE Deqing;SHI Liang;HE Wenjie(Wuhan Municipal Construction Group Co.,Ltd.,Wuhan 430056,China;School of Civil Engineering,Wuhan University,Wuhan 430072,China;State Key Laboratory of High Performance Civil Engineering Materials,Nanjing 210008,China;J4i.angsu Sobute New Materials Co.,Ltd.,Nanjing 211103,China)
出处 《混凝土》 CAS 北大核心 2019年第12期49-52,共4页 Concrete
基金 国家重点研发计划(2017YFB0309904) 国家重点基础研究发展计划(973)资助(2015CB655105) 江苏省自然科学基金资助(BK20161101,BK20160104,BK20171111) 重点工程研发项目资助(DG1-T02-2017,ZXGS-KJ-01)
关键词 TORRENT法 混凝土 空气渗透系数 氯离子扩散系数 电通量 TORRENT method concrete concrete air permeability diffusion coefficient of chloride ion electric flux
  • 相关文献

参考文献4

二级参考文献23

  • 1马昆林,谢友均,刘灿,许辉.混凝土固化氯离子影响因素的研究[J].混凝土,2004(6):20-21. 被引量:43
  • 2赵铁军.如何评定高性能混凝土的渗透性[J].混凝土,1995(3):19-21. 被引量:13
  • 3李志勇,姚佳良,张宇.关于混凝土抗渗性试验方法的研究[J].混凝土,2006(2):57-60. 被引量:24
  • 4Emmanuel Rozie're, Ahmed Loukili, Franc ois Cussigh. A performance based approach for durability of concrete exposed to carbonation [J]. Construction and Building Materials, 2009 (23): 190-199.
  • 5R. Torrent, M. Basheer, A. F. Gon?alves. CHAPTER 3. NON -DESTRUCTIVE METHODS TO MEASURE GASPERMEABILITY [R]. Non-Destructive Evaluation of the Penetrability and Thickness of the Concrete Cover RILEM TC 189-NEC: State-of-the-Art Report, 2007(5): 35-70.
  • 6F. Jacobs, M. Basheer, C. Andrade. CHAPTER 6. EFFECT OF MOISTURE AND TEMPERATURE ON NON - DESTRUCTIVE PENETRABILITY TESTS[R]. Non-Destructive Evaluation of the Penetrability and Thickness of the Concrete Cover RILEM TC 189-NEC: State-of-the-Art Report, 2007(5): 113-131.
  • 7Vincent Picandet, Abdelhafid Khelidj, Guy Bastian. Effect of axial compressive damage on gas permeability of ordinary and high-performance concrete [J]. Cement and Concrete Research, 2001(31): 1525-1532.
  • 8M.A. Sanjuh, R. Mufioz-Martialay. Oven-drying as a preconditioning method for air permeability test on concrete[J]. Materials Letters, 1996(27): 263-268.
  • 9Luis Ebensperger, Roberto Torrent. Medici6n "in situ" de la permeabilidad al aire del hormig6n: status quo [J]. Revista Ingenieria de Construcci6n, 2010, 25(3): 371-381.
  • 10Interim guidelines for the use of sekf-consolidatingconcrete in pre- cast/prestressed concrete institute member plants[S].United States of America: PCI.2003.

共引文献40