期刊文献+

Application of hybrid operating rooms for treating spinal dural arteriovenous fistula 被引量:7

Application of hybrid operating rooms for treating spinal dural arteriovenous fistula
下载PDF
导出
摘要 BACKGROUND A hybrid operating room(hybrid-OR)is a surgical space that combines a conventional operating room with advanced medical imaging devices.AIM To explore and summarize the technical features and effectiveness of the application of a hybrid-OR in dealing with spinal dural arteriovenous fistulas(SDAVFs).METHODS Eleven patients with SDAVFs were treated with the use of a hybrid-OR at the Department of Neurosurgery of our hospital between January 2015 and December 2018.The dual-marker localization technique was used in the hybrid-OR to locate the SDAVFs and skin incision,and the interoperative digital subtraction angiography(DSA)technique was used before and after microsurgical ligation of the fistulae in the hybrid-OR to verify the accuracy of obliteration.The patients were followed for an average of 2 years after the operation,and the preoperative American Spinal Cord Injury Association(ASIA)score and postoperative ASIA score at 6 mo after the operation were compared.RESULTS The location and skin incision of the SDAVFs were accurately obtained by using the dual-marker localization technique in the hybrid-OR in all patients,and there were no cases that required expansion of the range of the bone window in order to expose the lesions.Intraoperative error obliteration occurred and was identified in two patients by using the intraoperative DSA technique;therefore,the findings provided by the intraoperative DSA system significantly changed the surgical procedure in these two patients.With the assistance of the hybrid-OR,the feeding artery was correctly ligated in all cases,and the intraoperative error obliteration rate decreased from 18.2%(2/11)to 0%.All 11 patients were followed for an average of 2 years.The ASIA score at 6 mo after the operation was significantly improved compared with the preoperative ASIA score,and there were no patients with late recurrence during the follow-up.CONCLUSION Compared with intra-arterial embolization for the treatment of SDAVFs,hybrid-ORs can solve the problem of a higher incidence of initial failure and late recurrence.Compared with direct occlusion of SDAVFs in microsurgery,hybrid-ORs can take advantage of the intraoperative DSA system for locating the shunt and verifying the obliteration of fistulae in order to reduce the error obliteration rate.At this point,our experience suggests that the safety and ease of use make hybrid-ORs combined with microsurgery and intraoperative DSA systems an attractive modality for dealing with SDAVFs. BACKGROUND A hybrid operating room (hybrid-OR) is a surgical space that combines a conventional operating room with advanced medical imaging devices.AIM To explore and summarize the technical features and effectiveness of the application of a hybrid-OR in dealing with spinal dural arteriovenous fistulas(SDAVFs).METHODS Eleven patients with SDAVFs were treated with the use of a hybrid-OR at the Department of Neurosurgery of our hospital between January 2015 and December 2018.The dual-marker localization technique was used in the hybridOR to locate the SDAVFs and skin incision,and the interoperative digital subtraction angiography (DSA) technique was used before and after microsurgical ligation of the fistulae in the hybrid-OR to verify the accuracy of obliteration.The patients were followed for an average of 2 years after the operation,and the preoperative American Spinal Cord Injury Association (ASIA)score and postoperative ASIA score at 6 mo after the operation were compared.RESULTS The location and skin incision of the SDAVFs were accurately obtained by using the dual-marker localization technique in the hybrid-OR in all patients,and there were no cases that required expansion of the range of the bone window in order to expose the lesions.Intraoperative error obliteration occurred and was identified in two patients by using the intraoperative DSA technique;therefore,the findings provided by the intraoperative DSA system significantly changed the surgical procedure in these two patients.With the assistance of the hybridOR,the feeding artery was correctly ligated in all cases,and the intraoperative error obliteration rate decreased from 18.2%(2/11) to 0%.All 11 patients were followed for an average of 2 years.The ASIA score at 6 mo after the operation was significantly improved compared with the preoperative ASIA score,andthere were no patients with late recurrence during the follow-up CONCLUSION Compared with intra-arterial embolization for the treatment of SDAVFs,hybridORs can solve the problem of a higher incidence of initial failure and late recurrence.Compared with direct occlusion of SDAVFs in microsurgery,hybrid ORs can take advantage of the intraoperative DSA system for locating the shunt and verifying the obliteration of fistulae in order to reduce the error obliteration rate.At this point,our experience suggests that the safety and ease of use make hybrid-ORs combined with microsurgery and intraoperative DSA systems an attractive modality for dealing with SDAVFs.
出处 《World Journal of Clinical Cases》 SCIE 2020年第6期1056-1064,共9页 世界临床病例杂志
基金 the Tianjin Science and Technology Projects in Key Areas of Traditional Chinese Medicine,No.2018001.
关键词 Spinal DURAL ARTERIOVENOUS FISTULA HYBRID operating room Dual-marker localization TECHNIQUE Interoperative DSA TECHNIQUE RETROSPECTIVE study Spinal dural arteriovenous fistula Hybrid operating room Dual-marker localization technique Interoperative DSA technique Retrospective study
  • 相关文献

同被引文献27

引证文献7

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部