期刊文献+

UPLC-MS/MS法同时测定地表水中多种有机污染物 被引量:8

Simultaneous Determination of Organic Pollutants in Water byUPLC-MS/MS with Direct Injection
下载PDF
导出
摘要 采用超高效液相色谱-串联质谱法直接进样测定地表水中26种有机污染物,通过优化试验条件,使各目标化合物在1.00μg/L^100μg/L范围内线性良好,相关系数(r 2)>0.995,方法检出限为0.003μg/L^1.0μg/L。将该方法用于地表水样的测定,加标回收率为79.0%~120%,6次测定结果的RSD均<15%。 By optimizing the conditions of chromatography,mass spectrometry and filtration membrane selection,a method of determining 26 organic pollutants in surface water by ultra-high performance liquid chromatography-mass spectrometry with direct injection was established.The target compounds had a good linear relationship in the range of 1.00μg/L to 100μg/L,the correlation coefficient(r 2)was over 0.995.The detection limits ranged from 0.003μg/L to 1.0μg/L.When applying this method in surface water determination,the recoveries were from 79.0%to 120%,the relative standard deviation of the samples by 6 times duplicated measurement were all less than 15%.
作者 陈界江 邹云 高仪斌 李冰 李凤彩 CHEN Jie-jiang;ZOU Yun;GAO Yi-bin;LI Bing;LI Feng-cai(Suzhou Industrial Park Environmental Monitoring Station,Suzhou,Jiangsu 215027,China)
出处 《环境监测管理与技术》 CSCD 2020年第2期52-55,共4页 The Administration and Technique of Environmental Monitoring
基金 苏州市环保科技基金资助项目(B201704)。
关键词 有机污染物 直接进样 超高效液相色谱-串联质谱法 地表水 Organic pollutants Direct injection Ultra-high performance liquid chromatography-mass spectrometry Surface water
  • 相关文献

参考文献16

二级参考文献119

共引文献514

同被引文献93

引证文献8

二级引证文献18