摘要
UHPC-NSC组合式盖板涵能够在不明显增加结构造价的情况下,提高结构抗裂性能,并适应更大的跨度和填土高度;给出了考虑收缩徐变影响的组合式盖板涵设计方法,针对不同填土高度对盖板涵截面形式进行优化,考虑了土拱效应出现的条件,给出了填土高度2~10 m时的盖板涵标准化设计。
The composite slab culvert composed of ultra-high performance concrete and normal strength concrete(UHPC-NSC)can improve the structural crack resistance and increase the span and fill height without significantly increasing the structural cost.This paper gives a structural design method considering the effects of shrinkage and creep.According to the different fill heights,the cross-section form of the cover slab is optimized,and the conditions of soil arching effect are considered.The standard design of the cover culvert is given when the fill height is 2~10 m.
作者
曾田胜
晏班夫
吴海平
李冕
邵旭东
ZENG Tianshen;YAN Banfu;WU Haiping;LI Mian;SHAO Xudong(Guangdong Gaoen Expressway Company, Kaiping, Guangdong 529300, China;College of Civil Engineering, Hunan University, Changsha, Hunan 410000, China;Guangdong Provincial Transportation Planning and Design Institute Co. ,Ltd. , Guangzhou, Guangdong 510000, China)
出处
《公路工程》
北大核心
2020年第2期99-104,122,共7页
Highway Engineering
基金
广东省交通运输厅科技项目(科技2016-02-022)。