摘要 危险废物焚烧处置工程不断发展,因其生产特点,较易发生火灾危险并产生严重后果,尤其是危废料坑。根据危废料坑的生产存储特点,介绍了不同火灾探测器及可燃气体探测器的选型方案,分析了不同探测器的布置方法。结合实际工程中的应用,阐述不同方案的优缺点及工程设计过程中应考虑的问题,以期呈现优化的设计方案。 Hazardous waste incinerationproject is developing continuously.Because of its production characteristics,it is easy to cause fire hazards and serious consequences,especially hazardous waste pit.According to the production and storage characteristics of hazardous waste pit,the selection schemes of different fire detectors and combustible gas detectors are introduced,and the layout methods of different detectors are analyzed.Combined with the application in practical engineering,the advantages and disadvantages of different schemes and the problems to be considered in the engineering design are elaborated in order to present the optimized design scheme.
作者 王冲 Wang Chong(China Haisum Engineering Co.,Ltd.,Shanghai 200031,China)
出处 《山东化工》 CAS 2020年第7期167-168,176,共3页 Shandong Chemical Industry
关键词 火灾报警 危废料坑 探测器选型 可燃气体 fire alarm hazardous waste pit detector selection combustible gas