期刊文献+

高频超声测量正常成人球后3mm处的视神经鞘直径及其相关因素 被引量:6

Optic nerve sheath diameter 3 mm retrobulbarly measured on high-frequency ultrasound and its related factors in healthy adults
下载PDF
导出
摘要 目的探讨高频超声测量正常成人球后3 mm处的视神经鞘直径(ONSD)的正常参考值范围及其相关因素。方法选取193名正常成年人为研究对象,应用高频超声测量双眼眼球轴长及球后3 mm处的ONSD,计算ONSD的正常参考值范围。比较男女性之间、左右眼之间ONSD的差异,并分析ONSD与年龄、性别、身高、体重、腰围、头围的相关性。结果正常成人ONSD与性别、身高、体重、头围、体质指数呈正相关(均P<0.05),与年龄、腰围无相关性(均P>0.05)。正常成人ONSD为(3.55±0.48)mm(95%CI:3.47~3.63),其中正常成年女性ONSD为(3.42±0.45)mm(95%CI:3.33~3.51),正常成年男性ONSD平均值为(3.75±0.46)mm(95%CI:3.63~3.87)。左右眼之间的ONSD差异无统计学意义(P>0.05),男性ONSD大于女性(P<0.05)。结论高频超声测量正常成人ONSD为(3.55±0.48)mm,其中女性为(3.42±0.45)mm,男性为(3.75±0.46)mm。正常成人ONSD与性别、身高、体重、头围、体质指数相关。 Objective To explore the normal reference range of optic nerve sheath diameter(ONSD)3 mm retrobulbarly measured on high-frequency ultrasound in healthy adults and its related factors.Methods A total of 193 healthy adults were enrolled as research subjects,high-frequency ultrasound was used to measure binocular optic axis and ONSD 3 mm retrobulbarly,and the normal reference range of ONSD was calculated.ONSD was compared between males and females,or between left and right eyes.The correlation of ONSD with age,gender,height,body weight,waist circumference,and head circumference was analyze.Results Among healthy adults ONSD positively correlated with gender,height,body weight,head circumference,and body mass index(all P<0.05),and did not correlate with age or waist circumference(all P>0.05).ONSD was 3.55±0.48 mm in healthy adults,with a 95%CI of 3.47 to 3.63,3.42±0.45 mm in healthy female adults,with a 95%CI of 3.33 to 3.51,and 3.75±0.46 mm in healthy male adults,with a 95%CI of 3.63 to 3.87 mm.There was no statistically significant difference in ONSD between left and right eyes(P>0.05),males had greater ONSD than females(P<0.05).Conclusion ONSD measured on high-frequency ultrasound is 3.55±0.48 mm in healthy adults,3.42±0.45 mm in females and 3.75±0.46 mm in males.ONSD correlates with gender,height,body weight,head circumference,and body mass index in healthy adults.
作者 向红 亢春苗 穆靓 刘莉 XIANG Hong;KANG Chun-miao;MU Liang;LIU Li(Graduate School,Xi′an Medical University,Xi′an 710021,China;Department of Ultrasound,Shaanxi Provincial People′s Hospital,Xi′an 710068,China)
出处 《广西医学》 CAS 2020年第9期1065-1068,共4页 Guangxi Medical Journal
基金 陕西省重点研发计划(2018SF-180)。
关键词 视神经鞘直径 高频超声 正常成人 相关因素 Optic nerve sheath diameter High-frequency ultrasound Healthy adults Related factor
  • 相关文献

参考文献4

二级参考文献51

  • 1Liu D, Kahn M. Measurement and relationship of subarachnoid pressure of the optic nerve to intracranial pressures in fresh ca- davers. Am J Ophthalmol, 1993, 116: 548-556.
  • 2Dubourg J, Messerer M, Karakitsos D, et al. Individual patient data systematic review and meta-analysis of optic nerve sheath diameter ultrasonography for detecting raised intracranial pressure: protocol of the ONSD research group. Syst Rev, 2013, 2: 62.
  • 3Dubourg J, Javouhey E, Geeraerts T, et al. Ultrasonography of optic nerve sheath diameter for detection of raised intracrania| pressure: a systematic review and meta-analysis. Intensive Care Med, 2011, 37: 1059-1068.
  • 4Kalantari H, Jaiswal R, Bruck I, et al. Correlation of optic nerve sheath diameter measurements by computed tomography and mag- netic resonance imaging. Am J Emerg Med, 2013, 31: 1595-1597.
  • 5Geeraerts T. Noninvasive surrogates of intracranial pressure: anoth- er piece added with magnetic resonance imaging of the cere- brospinal fluid thickness surrounding the optic nerve. Crit Care, 2013, 17: 187.
  • 6Rajajee V, Vanaman M, Fletcher JJ, et al. Optic nerve ultrasound for the detection of raised intracranial pressure. Neurocrit Care, 2011, 15: 506-515.
  • 7Amini A, Kariman H, Arhami Dolatabadi A, et al. Use of the sono- graphic diameter of optic nerve sheath to estimate intraeranial pressure. Am J Emerg Med, 2013, 31: 236-239.
  • 8Maude RR, Hossain MA, Hassan MU, et al. Transorbital sono- graphic evaluation of normal optic nerve sheath diameter in healthy volunteers in Bangladesh. PLoS One, 2013, 8: e81013.
  • 9LashutkaM K, Chandra A, Murray HN, et al. The relationship of intraocular pressure to intracranial pressure. Ann Emerg Med, 2004, 43: 585-591.
  • 10Tamburrelli C, Anile C, Mangiola A, et al. CSF dynamic parame- ters and changes of optic nerve diameters measured by standard- ized echography. In: Till P, editor. Ophthalmic echography 13: proceedings of the 13th SIDUO Congress, Vienna, Austria, 1990. The Netherlands: Kluwer Academic Publishers, 1993: 101-109.

共引文献30

同被引文献44

引证文献6

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部