期刊文献+

电化学联合酸法对污泥脱水性能的影响 被引量:1

Effect of electrochemical combined acid method on sludge dewatering performance
下载PDF
导出
摘要 剩余污泥处理处置是当今社会的一大难点。要解决污泥产量大的问题,一个关键要素就是要提高脱水效率,改进脱水技术。探讨了电化学联合酸法对污泥脱水性能的影响,通过分析污泥含水率和毛细吸水时间来探究电解电压、极板间距、电解时间和极板插入深度对脱水的影响。实验结果显示:电化学联合酸法的最佳污泥脱水条件为极板间距6cm、极板插入深度6cm、电解时间30min、电解电压15V和pH为4。此时,污泥含水率降低9.04%,毛细吸水时间下降了42.6%。 The disposal and disposal of surplus sludge is a major difficulty in today's society.To solve the problem of large sludge production,a key element is to improve dewatering efficiency and improve dewatering technology.In this experiment,the effect of electrochemical combined acid method on the dewatering performance of sludge was investigated.The effects of electrolytic voltage,plate spacing,electrolysis time,and electrode insertion depth on dewatering were analyzed by analyzing the sludge moisture content and capillary water absorption time.The experimental results show that the optimal sludge dehydration conditions for the electrochemical combined acid method are 6cm,the insertion depth of the electrode plate is 6cm,the electrolysis time is 30min,the electrolysis voltage is 15V,and the pH is 4.At this time,the water content of the sludge decreased by 9.04%,and the capillary water absorption time decreased by 42.6%.
作者 李瑞玉 俞强 杨震 Li Ruiyu;Yu Qiang;Yang Zhen(School of Chemical Engineering,North China University of Science and Technology,Hebei Tangshan 063210)
出处 《云南化工》 CAS 2020年第5期28-30,共3页 Yunnan Chemical Technology
关键词 污泥脱水 电化学法 毛细吸水时间 含水率 Sludge dehydration electrochemical method capillary water absorption time moisture content
  • 相关文献

参考文献10

二级参考文献100

共引文献75

同被引文献13

引证文献1

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部