期刊文献+

大型张拉膜天线罩结构计算和实验验证 被引量:2

CALCULATION AND EXPERIMENT OF TENSIONED MEMBRANE STRUCTURE RADOME
下载PDF
导出
摘要 对负高斯曲面张拉膜天线罩结构刚强度进行仿真计算和实验验证。首先采用小弹性模量法进行找形分析,然后参考建筑结构荷载规范施加风载荷进行几何非线性分析计算,并根据膜结构技术规程进行刚强度校核,最后进行实物样机力学实验验证。将仿真计算结果和实验结果对比发现,加载后膜面应力最大误差为8.4%,膜面变形最大误差为5.1%,均在工程允许范围内,表明仿真计算方法的合理性。 Structure calculation and experiment have been performed on tensioned membrane structure radome based on curved surface with negative gauss.Form-finding analysis,geometry nonlinear calculation and experiment were carried out on a physical model.After all of the work,we found the membrane stress error is 8.4%between the calculation and the experiment,and the membrane displacement error is 5.1%between the calculation and the experiment.Error band is reasonable,so we are sure that the method of calculation is accurate.
作者 徐晓晨 戴苏亚 顾叶青 XU Xiao-chen;DAI Su-ya;GU Ye-qing(Nanjing Research Institute of Electronics Technology,Nanjing 210039,China)
出处 《复合材料科学与工程》 CAS 北大核心 2020年第7期114-116,122,共4页 Composites Science and Engineering
关键词 负高斯曲面 张拉膜 天线罩 找形分析 复合材料 curved surface with negative gauss tensioned membrane structure radome form-finding analysis composites