摘要
北京市某污水处理厂原设计规模为2×10^4m^3/d,出水标准为国标的一级A标准。本次提标改造及扩建工程中,在不新增占地的情况下,污水厂处理规模由2×10^4m^3/d扩建至8×10^4m^3/d,出水标准由原国标一级A标准提升到北京市地标《城镇污水处理厂水污染物排放标准》(DB 11/890—2012)的B标准。工程主体工艺采用A^2O-MBR工艺,深度处理采用臭氧紫外联合氧化。由于占地面积有限,本工程采用半地下建设形式,同时为保证改造期间不影响污水厂的正常生产,整个改造分期实施。实际运行表明,本工程出水水质完全满足设计要求,运行良好。
The original design scale of a wastewater treatment plant in Beijing was 2×10^4 m^3/d,and the standard of effluent was the national first class A standard.In the project of upgrading and expanding,the scale would be expanded from 2×10^4 m^3/d to 8×10^4 m^3/d without increasing the land occupation.The effluent standard would be upgraded from the national first class A standard to B level of Beijing local standard Discharge Standard of Water Pollutants for Municipal Wastewater Treatment Plants(DB 11/890-2012).The main process of the project adopted the A^2O-MBR,and the advanced treatment used ozone and ultraviolet combined oxidation.Due to the limited area,the project adopted a semi-underground construction form,and at the same time,to ensure that the normal production of the wastewater treatment plant was not affected during the transformation period,the whole transformation was implemented by stages.After the actual operation feedback,the effluent indicators of the project fully met the design requirements,and the actual operation state was good.
作者
秦栽根
闫萍
QIN Zai-gen;YAN Ping(Beijing Enterprises Water Group<China>Investment Limited,Beijing 100020,China)
出处
《中国给水排水》
CAS
CSCD
北大核心
2020年第14期113-117,共5页
China Water & Wastewater
关键词
半地下污水厂
提标改造及扩建
A^2O-MBR
semi-underground wastewater treatment plant
upgrading reconstruction and expansion
A^2O-MBR