摘要 发电厂中新型脱硫排烟一体式钢塔属于复杂的高耸薄壁结构,由于顶部截面突然变细,风荷载作用下极易产生较大振动,为了减小风致振动,提出了适用于脱硫排烟一体式钢塔的调谐质量阻尼器(tuned mass damper,TMD)减振方案.基于流固耦合理论,建立了结构场与流场计算模型,成功利用数值风洞方法计算了有无TMD结构的风振响应,并通过现场风振监测对数值方法的可靠性进行了验证.结果表明,该脱硫排烟一体式钢塔振型以局部或整体的平动、转动、屈曲与扭转为主,通过在塔体顶部设置TMD,位移动力响应最大值降低41%,均方根值降低75%.频谱分析表明,结构安装TMD后部分低频振型被激起,同时主频率对应的动力响应大大降低,TMD对于该脱硫排烟一体式钢塔可以起到较好的减振效果,为类似高耸薄壁结构的风振控制提供了参考. In power plant,the novel desulfurization and exhaust smoke integrated steel tower is a complex high thin-walled structure.With the top section suddenly becomes thinner,the steel tower is prone to vibration under wind loads.To reduce the wind-induced vibration of the structure,a tuned mass damper(TMD)vibration reduction scheme suitable for desulfurization and exhaust smoke integrated steel tower was proposed.Based on the fluid-structure interaction theory,structure field and flow field models were established.Wind vibration responses of the structure with or without TMD were calculated by using a numerical wind tunnel method,and the method was verified by on-site wind vibration monitoring.Results show that the vibration modes of the integrated steel tower were mainly local or overall translation,rotation,buckling and torsion.By installing a TMD on top of the tower,the peak value of the displacement dynamic response was reduced by 41%and the RMS value was reduced by 75%.Spectrum analysis results show that the low-frequency component of the structure was excited after installing TMD,and the dynamic response of the main frequency was greatly reduced.Vibration reduction effect was obvious for the desulfurization and exhaust smoke integrated steel tower with TMD,which provides a reference for wind-induced vibration control of similar structures.
作者 王希慧 宋波 陈磊 劳俊 王满生 WANG Xihui;SONG Bo;CHEN Lei;LAO Jun;WANG Mansheng(School of Civil and Resource Engineering,University of Science and Technology Beijing,Beijing 100083,China;Beijing International Cooperation Base for Science and Technology-Aseismic Research of the Rail Transit Engineering in the Strong Motion Area,Beijing 100083,China;Beijing Guodian Longyuan Environmental Protection Engineering,Co.Ltd.,Beijing 100039,China;Beijing Institute of Housing and Urban-Rural Construction Science and Technology,Beijing 100021,China)
出处 《哈尔滨工业大学学报》 EI CAS CSCD 北大核心 2020年第10期71-77,共7页 Journal of Harbin Institute of Technology
基金 国家重点研发计划(2017YFF0205003)。
关键词 脱硫塔 调谐质量阻尼器 数值风洞 现场监测 风振控制 desulfurization tower tuned mass damper numerical wind tunnel on-site monitoring wind-induced vibration control
  • 相关文献

参考文献10

二级参考文献93

共引文献100

同被引文献30

引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部