摘要
针对峄城国家气象观测站一年多来异地值守时出现的主要故障,主要包括地温故障、日照传感器故障、网络故障和降水现象仪故障等问题进行了分析,介绍了故障分析时的方式方法及处理结果,可用于日常气象观测时提高解决故障的效率,为业务工作人员在维修自动站时提供参考。
This paper analyzes the main faults of Yicheng National Meteorological Observation Station in different places for more than a year,including ground temperature fault,sunshine sensor fault,network fault and precipitation phenomenon meter fault.It also introduces the fault handling methods,which can be used in daily meteorological observation to improve the efficiency of fault resolution.This paper provides reference for business staff in the maintenance of automatic stations.
作者
崔云鹏
Cui Yunpeng(Yicheng Meteorological Bureau,Yicheng,Shandong 277300,China)
出处
《绿色科技》
2020年第16期169-170,173,共3页
Journal of Green Science and Technology
关键词
气象观测站
异地值守
故障分析
处理
meteorological observation station
remote duty
fault analysis
treatment