摘要 通过对不同配筋率的配筋方钢管混凝土短柱受压试验研究,在记录柱子的试验过程和静力性能变化后,给出了该类柱子轴压承载力和试件变形的结果。结果表明,相比配筋率ρ=1.45%试件而言,ρ=3.26%试件承载力提高5%左右,轴压刚度有很大程度的提高,平均提高近20%,延性有一定程度的改善。最终,讨论了方形截面的配筋钢管混凝土短柱受压承载力的计算方法,依据国内外相关规范/规程对其进行了计算,并在规范GB 50936—2014相关计算式基础上给出了简化计算式。 Through the compression test of reinforced square concrete-filled steel tube short columns with different reinforcement ratios,after recording the test process of the column and the change of static performance,the axial compression bearing capacity of the column and the deformation results of the specimen are given.The results show that,compared with the reinforcement ratioρ=1.45%,the bearing capacity ofρ=3.26%is increased by about 5%,the axial compression stiffness is greatly improved,and the average increase is nearly 20%,and the ductility is certain improvement.Finally,the calculation method of the compressive bearing capacity of reinforced concrete-filled steel tubular short columns with square cross-sections is discussed,and it is calculated according to relevant codes and regulations at home and abroad,and simplified calculations are given on the basis of the relevant formulas of the standard GB 50936:2014 formula.
作者 张信龙 陈勇 刘庆东 张玉琢 ZHANG Xinlong;CHEN Yong;LIU Qingdong;ZHANG Yuzhuo(China Northeast Architectural Design and Research Institute Co.,Ltd.,Shenyang 110000,China;College of Civil Engineering,Shenyang Jianzhu University,Shenyang 110168,China)
出处 《混凝土》 CAS 北大核心 2020年第12期11-14,20,共5页 Concrete
基金 十三五国家重点研发计划(2017YFC0703301)。
关键词 配筋钢管混凝土 方形短柱 轴压试验 极限承载力 bar-reinforced concrete filled steel tubular(RCFST) square section short column axial compression test ultimate bearing capacity
  • 相关文献

参考文献8

二级参考文献70

共引文献71

同被引文献16

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部