摘要
介绍了常温条件下(22~28℃),厌氧内循环反应器在某屠宰废水处理工程中的应用。该工程废水处理规模为4000 m^(3)/d。该反应器有机负荷可达5~6 kgCOD/(m^(3)·d),COD去除率达50%~55%。工程实践表明,反应器运行稳定,不需要加热,具有较明显的技术经济优势,可为其他屠宰行业废水处理提供借鉴。
The application of anaerobic internal circulation reactor in a slaughter wastewater treatment project with capability of 4000 m^(3)/d at normal temperature(22-28℃)were introduced.The reactor’s organic loading rates(VLR)can reach 5-6 kgCOD/(m^(3)·d),and the removal rate of COD is up to 50%-55%.The practice shows that the reactor operates stably and doesnot require heating.It is cost effective and can provide reference for other slaughter wastewater treatment.
作者
王立军
李兴奇
邵亚强
侯风文
张邦友
庞军
王传俊
WANG Li-jun;LI Xing-qi;SHAO Ya-qiang;HOU Feng-wen;ZHANG Bang-you;PANG Jun;WANG Chuan-jun(Shandong Chunjiang Environmental Science&Technology Co.L td.,Yantai 264006,China)
出处
《中国给水排水》
CAS
CSCD
北大核心
2021年第4期117-120,共4页
China Water & Wastewater
关键词
屠宰废水
常温
内循环厌氧反应器
slaughter wastewater
normal temperature
anaerobic internal circulation(IC)reactor