期刊文献+

EGMA-620W氧氮分析仪同时测定碳氮化钛粉末中氧氮含量 被引量:1

Determination of Oxygen and Nitrogen in TiCN Powders by EGMA-620W Oxygen and Nitrogen Analytical Instrument
下载PDF
导出
摘要 本文采用EGMA-620W氧氮分析仪,在自动分析条件下,研究加热功率、积分时间、助熔剂、样品量等实验条件对测试结果的影响,确定碳氮化钛粉末最佳的分析条件:加热功率6.5kW,分析时间90s,助熔剂选择锡,称样量在0.01-0.02g之间。在该条件下氧的加标回收率为96.2%-101.2%,氮的加标回收率为98.9%-99.7%,氧的精密度为2.64%,氮的精密度为1.19%,能满足实验要求。 This article used EGMA-620W oxygen and nitrogen analytical instrument,under automatic analysis conditions,investigating the influence of experimental conditions such as heating power,integration time,fluxes,sample weight to the test result,established the following conditions as the best:heating power was 6.5 kw,analysis time was 90s,flux was tin and sample mass should be controlled at 0.01~0.02g.Under this condition,the recovery rate of oxygen was between 96.2%and 101.2%,and that of nitrogen was between 98.9%and 99.7%.The precision of oxygen was about 2.64%,and that of nitrogen was about 1.19%,meeting the experiment requirements.
作者 柯雅真 Ke Yazhen(Xiamen Tungsten Co.,Ltd.,Xiamen 361009,Fujian)
出处 《福建冶金》 2021年第3期53-55,52,共4页 Fujian Metallurgy
关键词 碳氮化钛粉末 EGMA-620W氧氮分析仪 氧氮含量测定 TiCN powders EGMA-620W oxygen and nitrogen analytical instrument the measurement of Oxygen and nitrogen content
  • 相关文献

参考文献3

二级参考文献21

共引文献10

同被引文献2

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部