摘要
本文主要就环境监测中固定污染源废气氟化物的测定方法展开研究,通过介绍测定固定污染源废气氟化物的前期准备工作、具体实验步骤,得出实验结果并展开讨论,发现溶液的酸碱度及搅拌时长对测定结果造成一定影响。
This paper mainly studies the determination method of fluoride in waste gas from fixed pollution sources in environmental monitoring. By introducing the preliminary preparation work and specific experimental steps for the determination of fluoride in waste gas from fixed pollution sources, the experimental results are obtained and discussed. It is found that the pH of the solution and the stirring time have a certain impact on the determination results.
作者
冷雪
李庆
LENG Xue;LI Qing
关键词
氟化物
环境监测
废气
fluoride
Environmental monitoring
waste gas