摘要 传统外墙砖空鼓检测方法存在诸多缺点,推广无损检测方法势在必行。本文分别采用红外热像法和三维激光扫描法对建筑外墙进行无损检测,并对检测结果进行比对分析。结果表明:红外热像法可以高效检测外墙空鼓缺陷,但易受天气及外墙颜色影响;三维激光扫描法可有效弥补红外热像法的缺点,可用于修正红外热像法检测结果。本文研究成果可为建筑外墙砖无损检测提供一定的参考与借鉴。 There are many deficiencies in the traditional detection methods of the empty drum of exterior wall tiles,so it's imperative to promote non-destructive detection methods.Infrared thermal imaging method and 3-D laser scanning method are used for non-destructive detection of building exterior wall,and the test results are compared and analyzed.The results show that the infrared thermal imaging method can effectively detect the empty drum drawback of exterior wall,but it is easily affected by weather and exterior wall color.3-D laser scanning method can effectively make up for the deficiencies of infrared thermal imaging method,and can be used to correct the detection results of infrared thermal imaging method.The research results can provide references for non-destructive detection of building exterior titles.
作者 蔺颇 李亚茹 曹宏芳 LIN Po;LI Yaru;CAO Hongfang(Logistics Support Department,NanKai University,Tianjin 300071,China)
出处 《工程建设》 2021年第5期75-78,共4页 Engineering Construction
关键词 红外热像法 三维激光扫描 外墙砖 空鼓检测 无损检测 infrared thermal imaging method 3-D laser scanning exterior wall tiles empty drum detection nondestructive detection
  • 相关文献

参考文献7

二级参考文献40

  • 1赵鸿,冯平,周云,赵为民,赵鸣.红外热像技术检测建筑物外墙[J].结构工程师,2003(z1):357-360. 被引量:4
  • 2朱斌,沈筛军.红外热像技术检测建筑外墙饰面砖粘结缺陷[J].施工技术,2009,38(S1):449-451. 被引量:7
  • 3李增科,高井祥,姚一飞,王坚.GPS/INS紧耦合导航中多路径效应改正算法及应用[J].中国惯性技术学报,2014,12(6):782-787. 被引量:11
  • 4Lehmann B, Ghazi Wakili K, Frank T, et al. Effects of individual climatic parameters on the infrared thermography of buildings [J].Applied Energy, 2013, 110: 29-43.
  • 5Hoyano A, Asano K, Kanamaru T. Analysis of the sensible heat flux from the exterior surface of buildings using time sequential thermography [J]. Atmospheric Environment, 1999, 33(24): 3941-3951.
  • 6Datcu S, Ibos L, Candau Y, et al. Improvement of building wall surface temperature measurements by infrared thermography [J]. Infrared Physics & Technology, 2005, 46(6) : 451-467.
  • 7Youcef M H A L, Mazioud A, Bremond P, et al. A nondestructive method for diagnostic of insulated building walls using infrared thermography [C]// Defense and Security Symposium. International Society for Optics and Photonics, 2007:65410L-8.
  • 8Mahaboonpachai T, Kuromiya Y, Matsumoto T. Experimental investigation of adhesion failure of the interface between concrete and polymer-cement mortar in an external wall tile structure under a thermal load [J]. Construction and Building Materials, 2008, 22 (9) : 2001-2006.
  • 9Li Z, Yao W, Lee S, et al. Application of infrared thermography technique in building finish evaluation [J]. Journal of Nondestructive Evaluation, 2000, 19 (1) : 11-19.
  • 10Titman D J. Applications of thermography in non- destructive testing of structures [J]. NDT & E International, 2001, 34(2): 149-154.

共引文献117

同被引文献72

引证文献5

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部