基于自由曲面透镜阵列的共形整流罩动态像差校正

Dynamic Aberration Correction for Conformal Dome Based on Free-Form Lens Array
原文传递
导出
摘要 为了校正大长径比、大扫描视角共形整流罩引入的动态像差,提出了一种固定自由曲面透镜阵列校正器。通过设计透镜阵列校正器中各透镜自由曲面的面形和旋转角度,校正不同扫描视角大长径比共形整流罩引入的动态像差。实验结果表明,自由曲面透镜阵列校正器可以对长径比为1.2的共形整流罩实现±50°扫描视角的动态像差校正。这种新型校正器具有动态校正器和固定校正器的优点,可适用于扫描视角大、长径比大以及稳定性高的共形整流罩光学系统。 A fixed free-form lens array corrector is proposed in this paper to correct the dynamic aberration introduced by a conformal dome with large length-diameter ratio and large scanning angle.By designing the free-form surface shape and rotation angle of each lens of the lens array corrector,the dynamic aberration introduced by the large length-diameter ratio conformal fairing in different scanning angles is corrected.The experimental results show that the free-form lens array corrector can realize±50°scanning angle dynamic aberration correction for a conformal dome with a length-diameter ratio of 1.2.The new corrector has the advantages of both a dynamic corrector and a fixed corrector,and is suitable for a conformal dome optical system with a large scanning angle,a large length-diameter ratio and high stability.
作者 句源 赵春竹 朴明旭 郭玉 顾姗姗 郑汉青 Ju Yuan;Zhao Chunzhu;iao Mingxu;Guo Yu;Gu Shanshan;Zheng Hanqing(School of Opto-Electronic Engineering,Changchun University of Science and Technology,Changchun,Jilin 130022,China;Institute of Molecular Medicine,Peking University,Beijing 100871,China)
出处 《光学学报》 EI CAS CSCD 北大核心 2021年第9期199-207,共9页 Acta Optica Sinica
基金 国家自然科学基金(61805026) 吉林省教育厅“十三五”科学技术项目(JJKH20190580KJ) 长春理工大学青年科学基金(XQNJJ-2017-09)。
关键词 光学设计 共形光学 整流罩 自由曲面透镜 透镜阵列 optical design conformal optics dome free-form lens lens array
  • 相关文献

参考文献11

二级参考文献119

共引文献67

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部