摘要 A major goal of environmental agencies today is to conduct point-of-collection monitoring of excess inorganic phosphate(Pi)in environmental water samples for tracking aquatic“dead zones”caused by algae blooms.However,there are no existing commercial devices which have been miniaturized and are suitable for the point-of-need-testing(“PONT”)that is required to fully map a large region,such as the Florida Everglades.To solve this challenge,a reflection-mode fluorescence-sensing apparatus was developed,leveraging an environmentally sensitive fluorophore(MDCC)bound to a bacterial phosphate-binding protein to generate a fluorescent optical signal proportional to the concentration of(Pi)present.The combined end-to-end integrated sensor system had a response time of only 4 s,with minimal effects of common interfering agents and a linear range spanning from 1.1 to 64 ppb.To support easeof-use during PONT,the platform incorporated disposable wax-printed paper strip sample pads and a smartphone camera detection system.Since the EPA threshold is currently 30 ppb to prevent eutrophication,this system serves as a rapid test of whether a region is compliant.
出处 《Microsystems & Nanoengineering》 EI CSCD 2019年第1期164-173,共10页 微系统与纳米工程(英文)
基金 The authors would like to acknowledge the financial support by the National Science Foundation under NSF Cooperative Agreement(No.EEC-1648451 and No.EEC-1647837)。
关键词 SMART system apparatus
  • 相关文献

参考文献1

二级参考文献20

  • 1Engblom S O. The phosphate sensor. Biosensors and Bioelectronics, 1998, 13(9): 981-994.
  • 2Storer R A. In: Annual Book of ASTM standard, American Society for Testing and Materials: West Conshohocken, 1996, 1: 24-27.
  • 3Carey C M. Association constant for potassium-acid-phosphate determined by K and HP04 ion-selective electrodes. Journal of Dental Research, 1997, 76: 668-668.
  • 4Liu D, Chen W C, Yang R H, Shen G L, Yu R Q. Yang R H, Shen G L, Yu R Q. Polymeric membrane phosphate sensitive electrode based on binuclear organotin compound. Analytica Chimica Acta, 1997,338(3): 209-214.
  • 5de Marco R, Phan C. Determination of phosphate in hydroponic nutrient solutions using flow injection potentiometry and a cobaltwire phosphate ion-selective electrode. Talanta, 2003, 60(6): 1215- 1221.
  • 6Engblom S O. Determination of inorganic phosphate in a soil extract using a cobalt electrode. Plant and Soil, 1999,206(2): 173-179.
  • 7Xiao D, Yuan H Y, Li J, Yu R Q. Surface-modified coalt-based sensor as a phosphate-sensitive electorde. Analytical Chemistry, 1995,67(2): 288-291.
  • 8Chen Z, MarcoD R, Alexander P W. Flow-injection potentiometric detection of phosphates using a metallic cobalt wire ion-selective electrode. Analytical Communications, 1997,34(3): 93·95.
  • 9Zou Z W, Han J Y, Jang A, Bishop P L, Ahn C H. A disposable onchip phosphate sensor with planar cobalt micro electrodes on polymer substrate. Biosensors and Bioelectronics, 2007, 22(9-10): 1902-1907.
  • 10Fanjul-Bolado P, Queipo P, Lamas-Ardisana P J, Costa-Garcia A. Manufacture and evaluation of carbon nanotube modified screenprinted electrodes as electrochemical tools. Talanta, 2007, 74(3): 427-433.

同被引文献23

引证文献4

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部