摘要 机械式直流断路器弧后特性是表征其开断性能的重要参数。为获得直流开断过程中真空开关弧后电流峰值与时间、电流零点附近的di/dt、du/dt等影响规律,该文首先分析基于电流转移的机械式真空直流断路器弧后电流测量原理,设计机械式真空直流断路器弧后电流测量装置参数,搭建基于强迫过零方式的机械式直流开断实验平台,测量开断电流为1.5kA情况下机械式真空直流断路器弧后电流,讨论换向频率和恢复电压对弧后电流的影响。研究表明,基于电流转移的弧后电流测量装置可以有效测量弧后电流,弧后电流随着换向频率和恢复电压的增大而增大,恢复电压在相位上稍滞后弧后电流约100ns,且换向频率对弧后电流的影响大于恢复电压的影响,为断路器开断性能的优化研究提供了参考。 The post-arc characteristic of mechanical DC circuit breaker is an important parameter to characterize its breaking performance.In order to obtain the influence law of vacuum switch post-arc current,post-arc action time,di/dt and du/dt near current zero point during DC breaking process,this paper firstly analyzed the post-arc current of mechanical vacuum DC circuit breaker based on current transfer measurement principle.Then,the parameters of the mechanical DC circuit breaker arc current measurement device were designed,and a mechanical DC breaking experiment platform based on the forced zero crossing method was built.The mechanical vacuum DC circuit breaker arc was measured under the condition that the breaking current was 1.5kA,and the influence of the commutation frequency and the recovery voltage on post-arc current was discussed.The results show that the post-arc current measuring device based on current transfer can effectively measure the post-arc current.The increase of the commutation frequency and the recovery voltage will cause the post-arc current to increase.The recovery voltage slightly lags behind the post-arc current in phase by about 100 ns,and the change influence of the directional frequency on the post-arc current is greater than that of the recovery voltage,which provides a reference for the optimization research of the circuit breaker's breaking performance.
作者 程显 徐鹏飞 葛国伟 李鑫 田小倩 Cheng Xian;Xu Pengfei;Ge Guowei;Li Xin;Tian Xiaoqian(School of Electrical Engineering Zhengzhou University Zhengzhou,450000,China;Henan Power Transmission and Distribution Equipment and Electrical Insulation Engineering Research Center,Zhengzhou,450000,China)
出处 《电工技术学报》 EI CSCD 北大核心 2021年第16期3516-3524,共9页 Transactions of China Electrotechnical Society
基金 国家自然科学基金项目(51977195,51777025) 河南省优秀青年科学基金项目(2020YXQN45) 河南省高校高电压与放电学科引智基地建设项目(XCJD2021007)资助。
关键词 弧后电流 机械式断路器 直流开断 换向频率 恢复电压 Post-arc current mechanical circuit breaker DC interruption commutation frequency recovery voltage
  • 相关文献

参考文献17

二级参考文献156

共引文献455

同被引文献161

引证文献12

二级引证文献39

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部