期刊文献+

关于食用盐测碘的方法探讨 被引量:1

Discussion on the Method of Measuring Iodine in Edible Salt
下载PDF
导出
摘要 目前未出台关于自动电位滴定测碘的标准,为探讨此方法测碘的可行性,本文采用GB/T 13025.7-2012直接滴定法和自动电位滴定法分别对碘标准溶液和食盐中的碘含量进行测定。当样本量大,追求方便快捷时可使用自动电位滴定法测定。 At present,there is no standard for automatic potentiometric titration to measure iodine.In order to explore the feasibility of this method for measuring iodine,this paper used GB/T 13025.7-2012 direct titration method and automatic potentiometric titration method to measure iodine content in iodine standard solution and salt respectively.When the sample size is large and the pursuit of convenience and quickness,automatic potentiometric titration method can be used for determination.
作者 周雪琪 岳元媛 刘文倩 王茹 谢丹丹 欧阳华峰 Zhou Xueqi;Yue Yuanyuan;Liu Wenqian;Wang Ru;Xie Dandan;Ouyang Huafeng(Xuetian Salt Industry Group Co.,Ltd.,Changsha,Hunan,410004;Hunan Well and Rock Salt Engineering and Technological Research Center,Changsha,Hunan,410004;Hunan Light Industry Salt Industry Group Technological Center,Changsha,Hunan,410004)
出处 《中国井矿盐》 CAS 2021年第6期30-32,共3页 China Well and Rock Salt
关键词 自动电位滴定 食盐 碘含量 Automatic potentiometric titration edible salt iodine content