期刊文献+

永磁电机直驱控制系统在带式输送机上的应用 被引量:2

Application of Permanent Magnet Motor Direct Drive Control System in Belt Conveyor
下载PDF
导出
摘要 针对带式输送机驱动系统在启动过程中稳定性差、负载变化大、功率不平衡的不足,提出了一种新的带式输送机永磁电机直驱控制系统,对该直驱控制系统结构布局、工作原理等进行了分析。实际应用结果表明,新的直驱控制系统能够有效解决输送机启动过程中功率不平衡及启动稳定性差的问题,同时将输送机运行时的能耗降低了约29%,对提升井下输送机的运输安全性和经济性具有十分重要的意义。 Aiming at the disadvantages of poor stability,large load change and unbalanced power in the starting process of belt conveyor drive system,a new permanent magnet motor direct drive control system for belt conveyor was proposed.This paper analyzed the structure layout and working principle of the direct drive control system.The practical application results show that the new direct drive control system can effectively solve the problems of power imbalance and poor starting stability in the starting process of the conveyor,and reduce the energy consumption of the conveyor by about 29%,which is of great significance to improve the transportation safety and economy of the underground conveyor.
作者 高海生 GAO Haisheng(Shenyang Coal Industry(Group)Machinery Manufacturing Co.,Ltd.,Shenyang 110123,Liaoning,China)
出处 《能源与节能》 2021年第11期177-178,共2页 Energy and Energy Conservation
关键词 带式输送机 永磁电机 直驱控制 功率不平衡 belt conveyor permanent magnet motor direct drive control power imbalance
  • 相关文献

参考文献4

二级参考文献75

  • 1刘军,楚小刚,白华煜.基于参考磁链电压空间矢量调制策略的永磁同步电机直接转矩控制研究[J].电工技术学报,2005,20(6):11-15. 被引量:47
  • 2席裕庚.复杂工业过程的满意控制[J].信息与控制,1995,24(1):14-20. 被引量:47
  • 3贾洪平,贺益康.永磁同步电机滑模变结构直接转矩控制[J].电工技术学报,2006,21(1):1-6. 被引量:98
  • 4王庆义,尹泉,刘杰,万淑芸.一种基于定子电流重构的死区补偿技术[J].电力电子技术,2006,40(2):73-75. 被引量:4
  • 5张兴,张崇巍.PWM整流器及其控制[M].北京:机械工业出版社,2003.
  • 6Rodriguez J, Dixon J, Espinoza J, et al. PWM regenerative rectifiers, state of the art[J]. IEEE Trans. on Industrial Electronics, 2005, 52(1): 5-22.
  • 7Chen B, Joos G. Direct power control of active filters with averaged switching frequency regulation[J]. IEEE Trans. on PowerElectron, 2008, 23(6): 2729-2737.
  • 8Chaves M, Margato E, Sliva J F. Fast optimum-predictive control and capacitor voltage balancing strategy for bipolar back-to-back NPC converters in high-voltage direct current transmission systems[J]. The Institution of Engineering and Technology, 2011, 5(3): 368-375.
  • 9Blasko V, Kaura V. A new mathematical model and control of a three-phase ac-dc voltage source converter [J]. IEEE Trans. on Power Electron, 1997, 12(1): 116-123.
  • 10Noguchi T, Tomiki H; Kondo S. Direct power control of PWM converter without power-source voltage sensors [J]. IEEE Trans. on Industry Applications, 1998, 34(3): 473-479.