期刊文献+

先进测量实验区素地电磁环境测试与分析 被引量:1

Measurement and analysis of electromagnetic environment in plain ground in advanced measurement experimental area
下载PDF
导出
摘要 素地电磁环境实测与分析对于先进测量实验室建设意义重大,可用于指导先进测量实验室建设选址的适用性和电磁环境影响控制设计。以中国计量科学研究院实验基地先进测量实验区为研究对象,制定测试方案,对实验区素地电磁环境特性进行测试。结果表明,该实验区建设地块四周工频磁场磁感应强度均大于0.01μT,动力站和10 kV变电站周边更大,实验区核心位置磁感应强度基本在0.01μT附近,为满足实验室工频磁场容许值,建设地点应沿周边道路退让一定距离,并应远离动力站和变电站,对工频磁场环境要求更为严格的实验室应依据测试数据采取必要的屏蔽处理措施;实验区所有位置的射频电场强度26~3000 MHz频段均小于1 V/m,最大场强为0.5037 V/m@26.3125 MHz,该频段射频电场强度对实验室建设影响不大,无需做任何防护处理措施。 The measurement and analysis of the electromagnetic environment is of great significance for the construction of the advanced measurement laboratory,which can be used to guide the applicability of the construction site selection of the advanced measurement laboratory and the design of the electromagnetic environment impact control.Taking the advanced measurement experimental area of the experimental base of National Institute of Metrology as the research object,the test scheme is made to test the electromagnetic environment characteristics of the experimental area.The results show that the magnetic induction intensity of power frequency magnetic field around the construction site of the experimental area is greater than 0.01μT.The magnetic induction intensity around the power station and 10 kV substation is larger.The magnetic induction intensity at the core of the experimental area is basically around 0.01μT.in order to meet the allowable value of power frequency magnetic field of the laboratory,the construction site should retreat a certain distance along the surrounding road,and should be far away from the power station and substation For a more strict laboratory,necessary shielding measures should be taken according to the test data;the RF electric field strength of all positions in the experimental area is less than 1 V/m in the 26-3000 MHz frequency band,and the maximum electric field strength is 0.5037 V/m@26.3125 MHz,which has little impact on the laboratory construction and does not need any protective measures.
作者 汪洪军 黄攀 董玉平 孔伟 刘延 WANG Hongjun;HUANG Pan;DONG Yuping;KONG Wei;LIU Yan(National Institute of Metrology,China,Beijing 100029,China;Beijing Branch of Nanjing Bosen Technology Co.,Ltd.,Beijing 100027,China)
出处 《中国测试》 CAS 北大核心 2021年第12期1-5,63,共6页 China Measurement & Test
基金 财政专项运行经费支持项目(ZYZJ1603)。
关键词 实验室 素地 电磁环境 现场测试 laboratory plain ground electromagnetic environment field test
  • 相关文献

参考文献9

二级参考文献88

共引文献65

同被引文献12

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部