火电机组跳闸原因分析及处理

Cause Analysis and Treatment of Trip of Thermal Power Unit
下载PDF
导出
摘要 针对某300 MW超临界机组跳闸事件,进行了原因分析,确定是由于电泵勺管电动执行机构卡涩,就地手动调节引起电泵再循环门联锁关、开动作,造成汽包水位下降至动作值,导致锅炉MFT动作,机组跳闸,并制定了相应的防范措施。 The cause of tripping event of a 300 MW supercritical unit is analyzed.Due to the jamming of the electric actuator of the scoop pipe of the electric pump,the local manual adjustment caused the interlocking closing and opening of the recirculation valve of the electric pump,which decrease the drum water level to the action value,resulting in the action of the boiler MFT and the tripping of the unit.Corresponding preventive and improvement measures are formulated.
作者 俞凯耀 金波 YU Kaiyao;JIN Bo(Zhejiang International Maritime Vocational and Technical College,Zhoushan 316000,China;Shenhua Guohua(Zhoushan)Power Generation Co.,Ltd.,Zhoushan 316000,China)
出处 《电工技术》 2021年第23期176-177,180,共3页 Electric Engineering
基金 2020年浙江省教育厅一般科研项目“基于发电系统感温元件更换通用性的研究”(编号Y202045608) 2021年浙江省大学生科技创新项目“降低发电厂电泵转速波动装置的研究与设计”(编号2021R479006)。
关键词 跳闸 电泵 改进 trip electric pump improvement