开关转换器输出浪涌电流引发的启动台阶问题技术研究 被引量:2

Preventing Start up Issue Due to Output Inrush in Switching Converters
下载PDF
导出
摘要 所研制的低压大电流DCDC开关转换器电路在用户处使用,由于容性负载接近1 000 μF,在低温下表现为大电流台阶启动,甚至无法启动。针对该现象,本文开展了大电流开关电源的启动阶段机理分析和实验验证,并提出了针对用户使用条件下的启动台阶现象的解决办法。 Since the capacitive load is close to 1 000 μF,the low-voltage and high-current DCDC switching converter circuit developed can not even start at low temperature.In view of this phenomenon,this paper carries out the mechanism analysis and experimental verification of the start-up phase of the high-current switching power supply,and puts forward the solution to the start-up step phenomenon under the user’s use conditions.
作者 刘文韬 张洁 苟超 彭克武 陈波 胡袁彬 LIU Wen-tao;ZHANG Jie;GOU Chao;PENG Ke-wu;CHEN Bo;HU Yuan-bin(Sichuan Institute of Solid-State Circuits,China Electronics Technology Group Corp.,Chongqing 400060)
出处 《环境技术》 2021年第6期131-135,共5页 Environmental Technology
关键词 大电流DCDC转换器 浪涌电流 大负载电容 台阶启动 high current DC-DC convertor surge current high-load capacitance step start