摘要 目的探讨Dolphin在调强放射治疗(IMRT)计划三维剂量验证中的应用价值。方法随机选取医院2020年1—8月收治的15例肿瘤患者,其中盆腔部肿瘤患者、头颈部肿瘤患者、肺部肿瘤患者各5例,盆腔部和头颈部肿瘤患者治疗计划采用的是容积旋转调强放射治疗(VMAT),肺部肿瘤患者治疗计划采用的是动态IMRT,将所有患者的治疗计划分别在MOSAIQ系统质量保证(QA)模式下用Dolphin进行实际测量,然后将结果导入Compass软件,最终对比分析Dolphin实测剂量与计划剂量在患者定位CT图像上的剂量分布、剂量体积直方图(DVH)和三维Gamma(3%,3 mm)值。结果Dolphin实测剂量与计划剂量在患者定位CT图像上的三维剂量分布基本一致,DVH基本吻合,且两者肿瘤靶区和正常组织器官的Gamma通过率均大于95%。结论临床可将Dolphin用于放射治疗计划三维剂量验证中,其较传统的二维剂量验证系统和三维剂量验证系统(如Mapcheck和ArcCHECK)操作更加简单、快捷。 Objective The application value of Dolphin in the three-dimensional dose validation in intensity modulated radiation therapy(IMRT) plan was explored. Methods 15 patients with cancers received and treated in the hospital from January to August in 2020 were randomly selected, among them, 5 patients were diagnosed with pelvic tumor, 5 patients were diagnosed with head and neck tumor and the other 5 patients were diagnosed with lung tumor. Volumetric modulated arc therapy(VMAT) was used in the treatment plans for patients with pelvic and head and neck tumors, and dynamic IMRT was used in the treatment plans for patients with lung tumor. 15 patients’ treatment plans were measured with Dolphin in MOSAIQ system quality assurance(QA) mode, and the results were imported into Compass software. Finally, the dose distribution of patient positioning CT images, dose volume histogram(DVH) and threedimensional Gamma(3%, 3 mm) value between Dolphin measured dose and planned dose were compared and analyzed. Results The three-dimensional dose distribution of Dolphin measured dose and planned dose on CT images of patients was basically consistent, the DVH was basically consistent, and the Gamma pass rates of tumor target area and normal tissues and organs for both were all greater than 95%. Conclusions Dolphin can be used in the three-dimensional dose verification of radiotherapy plan in clinic. Compared with the traditional two-dimensional dose verification system and three-dimensional dose verification system(such as Mapcheck and ArcCHECK), it is simpler and faster to operate.
作者 陈俊颖 夏火生 赵剑 王莉新 Chen Junying;Xia Huosheng;Zhao Jian;Wang Lixin(Radiotherapy Department,Beijing Yanhua Hospital,Beijing 102500,China)
出处 《医疗装备》 2022年第3期32-34,38,共4页 Medical Equipment
关键词 DOLPHIN 容积旋转调强放射治疗 动态调强放射治疗 吸收剂量 剂量验证 Dolphin Volumetric modulated arc therapy Dynamic intensity modulated radiation therapy Absorbed dose Dose verification
  • 相关文献

参考文献7

二级参考文献51

  • 1戴建荣,胡逸民,张红志,关莹,张可,王闯.针对患者调强放射治疗计划的剂量学验证[J].中华放射肿瘤学杂志,2004,13(3):229-233. 被引量:65
  • 2Daniel L,Misbah G,Di Yan,et al. Evaluation of a 2D diode array for IMRT quality assurance [J]. Radiotherapy and Oncology,2004,70 (12):199-206.
  • 3李明辉.调强放疗技术进展[N].中国医学论坛报,2008-03-06(B05).
  • 4沈文斌,祝淑钗,李任,李娟,邱嵘,王玉祥,苏景伟.胸中下段食管癌三维适形放疗所致放射性肺损伤相关因素分析[J].中华放射肿瘤学杂志,2007,16(5):335-340. 被引量:21
  • 5Ezzell GA, Galvin JM, Low D, et al. Guidance document on de- livery, treatment planning, and clinical implementation of IMRT: report of the IMRT Subcommittee of the AAPM Radiation Therapy Committee [ J ]. Med Phys,2003, 30:2089- 2115.
  • 6Bucciolini M, Bounamici FB, Casati M. Verification of IMRT fields by film dosimetry [ J ]. Med Phys,2004, 31 ( 1 ) : 161 - 168.
  • 7Stathakis S. Ionization chamber array for patient specific VMAT, Tomotherapy and IMRT QA [ J ]. Phys Conf Set, 2010,250 : 12- 29.
  • 8Low DA, Harms WB, Mutic S, et al. A technique for the quanti- tative evaluation of dose distributions [ J]. Med Phys, 1998, 25 (5) :656-661.
  • 9Otto K. Volmnetric modulated arc therapy: IMRT in a single gantryarc[J]. MedPhys,2008, 35(1) :310-317.
  • 10Verbakel WF, Senan S, Cuijper JP, et at. Rapid delivery of stereotactic radiotherapy for peripheral lung tumors using volumetric intensity-modulated arcs [ J ]. Radiother Oncol, 2009, 93 : 122- 124.

共引文献98

同被引文献31

引证文献3

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部