摘要 偏磁电流经变压器中性点入侵电力系统后,线路CT将发生一定程度的饱和,影响二次系统的测量、控制等环节,严重时甚至会诱发系统继电保护的误拒动,对电力系统的安全稳定运行造成严重威胁。为此,提出了一种基于相空间轨迹识别的继电保护改进方案。首先,分析直流偏磁对保护用CT的不利影响。在此基础上,以线路保护与变压器保护为例,揭示直流偏磁影响下继电保护的失效机理。进一步地,利用相空间轨迹不受时域饱和影响的特点,提出了一种基于相空间轨迹识别的继电保护改进方案,使得所提方案能有效应对CT饱和导致的保护失效难题。最后,以典型保护失效场景为例,对比传统方法与所提改进方案的保护动作情况,验证了所提方案的有效性及优越性。 Once DC with high amplitude penetrates the power system through the neutral point of the transformer,line CT will saturate to some extent.This saturation will affect the measurement and control of the secondary system.When the DC bias is very serious,it will even induce an incorrect relay protection of the system.This poses a serious threat to the safe and stable operation of the power system.Therefore,an improved scheme of relay protection based on phase space trajectory identification is proposed.First,the adverse effect of DC bias on protective CT is analyzed.Then,taking line protection and transformer protection as examples,the failure mechanism of relay protection under the influence of DC bias is revealed.An improved relay protection scheme based on phase space trajectory identification is proposed,one which can effectively deal with the protection failure problem caused by CT saturation,based on the characteristic that the phase space trajectory is not affected by time-domain saturation.Finally,taking a typical protection failure scenario as an example,the effectiveness and superiority of the proposed scheme are verified by comparing the protection actions of the traditional method and the proposed scheme.
作者 马书民 戎子睿 林湘宁 李正天 汪致洵 张培夫 徐海波 MA Shumin;RONG Zirui;LIN Xiangning;LI Zhengtian;WANG Zhixun;ZHANG Peifu;XU Haibo(State Key Laboratory of Advanced Electromagnetic Engineering and Technology,(Huazhong University of Science and Technology),Wuhan 430074,China;EAST GROUP CO.,LTD.,Dongguan 523808,China)
出处 《电力系统保护与控制》 EI CSCD 北大核心 2022年第8期86-98,共13页 Power System Protection and Control
基金 国家自然科学基金面上项目资助(51877088) 东莞市引进创新科研团队计划项目资助(201536000200036)。
关键词 直流偏磁 CT饱和 线路保护 相空间轨迹识别 继电保护改进方案 DC bias CT saturation line protection phase space trajectory recognition improvement scheme of relay protection
  • 相关文献

参考文献26

二级参考文献331

共引文献538

同被引文献219

引证文献15

二级引证文献58

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部